MAAS power query does not work for Python power drivers
Bug #1485677 reported by
Andres Rodriguez
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
MAAS |
Fix Released
|
Critical
|
Newell Jensen |
Bug Description
The MAAS power querying mechanism is not working for the MAAS python power drivers. This was found right after landing the IPMI python power driver.
Related branches
lp:~allenap/maas/revert-ipmi-power-driver
- Andres Rodriguez (community): Approve
-
Diff: 654 lines (+130/-469)6 files modifiedetc/maas/templates/power/ipmi.conf (+4/-0)
etc/maas/templates/power/ipmi.template (+110/-0)
src/provisioningserver/drivers/power/__init__.py (+0/-2)
src/provisioningserver/drivers/power/ipmi.py (+0/-154)
src/provisioningserver/drivers/power/tests/test_ipmi.py (+0/-312)
src/provisioningserver/power/tests/test_poweraction.py (+16/-1)
lp:~andreserl/maas/lp1485677
- Gavin Panella (community): Approve
-
Diff: 15 lines (+0/-5)1 file modifiedsrc/provisioningserver/rpc/power.py (+0/-5)
Changed in maas: | |
importance: | Undecided → Critical |
milestone: | none → 1.9.0 |
Changed in maas: | |
status: | New → Triaged |
Changed in maas: | |
status: | Triaged → Fix Committed |
Changed in maas: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
Andres,
Can you please let me know what the error is. Using the same code that was reverted, I do not get any power query errors/issues on the hardware that I have been testing on.
Thanks.