PCBnew: Incorrect Unrouted Net count
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
KiCad |
Fix Released
|
Critical
|
Tomasz Wlostowski |
Bug Description
After pouring grounds, the unrouted net count at the bottom of the screen is incorrect.
The attached image illustrates this; there is a floating island that is associated with the ground net, but isn't actually connected. Additionally, there is no rat line to indicate this, and there is Unrouted count at the bottom of the screen is zero, when it should be 1.
Expected:
1) A rat line connecting the two nets.
2) The Unrouted net count to be 1.
We are using the latest kicad from master.
===
Application: pcbnew
Version: (6.0.0-
Libraries:
wxWidgets 3.0.4
libcurl/7.60.0 OpenSSL/1.1.0h zlib/1.2.11 libidn2/2.0.5 libpsl/0.20.2 (+libidn2/2.0.4) nghttp2/1.32.0
Platform: Linux 4.17.4-1-ARCH x86_64, 64 bit, Little endian, wxGTK
Build Info:
wxWidgets: 3.0.4 (wchar_t,wx containers,
Boost: 1.67.0
OpenCASCADE Community Edition: 6.9.1
Curl: 7.60.0
Compiler: GCC 8.1.1 with C++ ABI 1012
Build settings:
USE_
USE_
KICAD_
KICAD_
KICAD_
KICAD_
BUILD_
KICAD_
KICAD_
KICAD_SPICE=ON
Changed in kicad: | |
status: | Fix Committed → Fix Released |
Note: the rest of the trace that is marked floating simply connects to another GND pad.