Collector back pressure not working
Bug #1528380 reported by
Megh Bhatt
This bug affects 4 people
Affects | Status | Importance | Assigned to | Milestone | ||
---|---|---|---|---|---|---|
Juniper Openstack | Status tracked in Trunk | |||||
R2.20 |
Fix Committed
|
High
|
Megh Bhatt | |||
R2.21.x |
Fix Committed
|
High
|
Megh Bhatt | |||
R2.22.x |
Fix Committed
|
High
|
Megh Bhatt | |||
Trunk |
Fix Committed
|
High
|
Megh Bhatt |
Bug Description
contrail-collector back pressure mechanism to handle generators overwhelming collector is not working. Issue is that the watermark levels are marked as INVALID and the locally cached drop levels are initialized also at INVALID. So the drop levels don't change and hence the defer callbacks for both the queue's are not called.
Changed in juniperopenstack: | |
assignee: | nobody → Megh Bhatt (meghb) |
information type: | Proprietary → Public |
To post a comment you must log in.
Review in progress for https:/ /review. opencontrail. org/15957
Submitter: Megh Bhatt (<email address hidden>)