with new cpu_pipeline, cpu_util samples dropped for multiple instances

Bug #1202756 reported by Eoghan Glynn
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Ceilometer
Fix Released
Critical
Eoghan Glynn

Bug Description

When multiple instances exist, the ordering of pipleline handle_sample() and flush() calls on the transformer cause cpu_util samples for subsequent instances to be dropped.

Eoghan Glynn (eglynn)
Changed in ceilometer:
status: New → Confirmed
status: Confirmed → In Progress
assignee: nobody → Eoghan Glynn (eglynn)
milestone: none → havana-3
importance: Undecided → Critical
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to ceilometer (master)

Reviewed: https://review.openstack.org/37724
Committed: http://github.com/openstack/ceilometer/commit/879a4cc03252b2fc51d2efa5d78013a6e1e45994
Submitter: Jenkins
Branch: master

commit 879a4cc03252b2fc51d2efa5d78013a6e1e45994
Author: Eoghan Glynn <email address hidden>
Date: Thu Jul 18 16:53:26 2013 +0000

    Avoid dropping cpu_util for multiple instances.

    Fixes bug 1202756

    When multiple instances exist, the ordering of pipleline
    handle_sample() and flush() calls on the transformer caused
    cpu_util samples for subsequent instances to be dropped.

    Change-Id: I1d8198c0c12d99a2ffde11e4321d29723c947178

Changed in ceilometer:
status: In Progress → Fix Committed
Thierry Carrez (ttx)
Changed in ceilometer:
status: Fix Committed → Fix Released
Thierry Carrez (ttx)
Changed in ceilometer:
milestone: havana-3 → 2013.2
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.