Bug Description

Imagine nodepool is setup with min-ready:0, and working because zuul know of said job (gate-fastdraw-docs). However, if zuul is restarted, and said jenkins node is offline, it assumes the job is not registered:

2014-04-04 18:24:51,516 DEBUG zuul.Gearman: Function build:gate-fastdraw-docs is not registered (negative ttl in effect)
2014-04-04 18:24:51,516 ERROR zuul.Gearman: Job <gear.Job 0x7f2d48141390 handle: None name: build:gate-fastdraw-docs unique: ec976774806c407499e8cd780e8e72d3> is not registered with Gearman

If, nodepool is reconfigured with min-ready:1, everything will work as expected.