Gives error on Windows 7 64-bit

Bug #803905 reported by Tambet Väli
10
This bug affects 2 people
Affects Status Importance Assigned to Milestone
valide
New
Undecided
Unassigned

Bug Description

On starting up:

---------------------------
valide.exe - Entry Point Not Found
---------------------------
The procedure entry point gzdirect could not be located in the dynamic link library zlib1.dll.
---------------------------
OK
---------------------------

Revision history for this message
Dev Master (kdean) wrote :

I had the same problem except I am on Windows XP. By placing a copy of zlib1.dll at C:\WINDOWS\system32 fixed the problem and the IDE started up. There is more then one approach to fix the problem. This was just quick and dirty.

Revision history for this message
mydoghasworms (dumace) wrote :

That last solution did not work for me. I used the zlib1.dll provided by the Gnu-Win32 project.

Revision history for this message
mydoghasworms (dumace) wrote :

But I did get it working by adding zlib1.dll in C:\Program Files (x86)\valide-0.7.1\bin.

To post a comment you must log in.
This report contains Public information  
Everyone can see this information.