DBus error signals should send the object id when available
Bug #691292 reported by
Natalia Bidart
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Ubuntu One Control Panel |
Fix Released
|
Medium
|
Natalia Bidart | ||
ubuntuone-control-panel (Ubuntu) |
Fix Released
|
Medium
|
Natalia Bidart |
Bug Description
The signals are:
DeviceSettingsC
DeviceRemovalError
VolumeSettingsC
Related branches
lp:~nataliabidart/ubuntuone-control-panel/more-logging-and-ids
- Roman Yepishev (community): Approve (code)
- Martin Albisetti (community): Approve
-
Diff: 330 lines (+69/-24)5 files modifiedbin/ubuntuone-control-panel-backend (+2/-0)
bin/ubuntuone-control-panel-gtk (+4/-3)
ubuntuone/controlpanel/backend.py (+9/-1)
ubuntuone/controlpanel/dbus_service.py (+47/-19)
ubuntuone/controlpanel/integrationtests/test_dbus_service.py (+7/-1)
Changed in ubuntuone-control-panel: | |
status: | New → In Progress |
importance: | Undecided → Medium |
assignee: | nobody → Naty Bidart (nataliabidart) |
Changed in ubuntuone-control-panel (Ubuntu): | |
status: | New → Triaged |
status: | Triaged → In Progress |
importance: | Undecided → Medium |
assignee: | nobody → Naty Bidart (nataliabidart) |
Changed in ubuntuone-control-panel: | |
status: | In Progress → Fix Committed |
Changed in ubuntuone-control-panel: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
This bug was fixed in the package ubuntuone- control- panel - 0.1.0-0ubuntu1
--------------- control- panel (0.1.0-0ubuntu1) natty; urgency=low
ubuntuone-
* debian/control
- depends on ubutuone-client >= 1.5.1
- depends on ubuntu-sso-client >= 1.1.7
* New upstream release.
[ Natalia B. Bidart <email address hidden> ]
* Updated list of messages to be shown on the overview panel (LP:
#690379).
* Implemented callback for failure when loading devices.
* Added a spinner on every UbuntuOneBin to be shown while loading the
panel content.
* Devices can now be removed (LP: #691295).
* Migrated dbus_client to use non-deprectaed SSO D-Bus API.
* Added clear_credentials to dbus_client module.
* Implemented devices tab (LP: #690649).
* Maximum size is set using geometry hints (LP: #683164).
* Added logging to dbus_service and backend.
* Error signals now sent the object id when available (LP: #691292).
* After machine was added, Folders page is shown (LP: #674459).
* VolumesInfoError signal is now handled (LP: #690292).
* When FileSyncStatusError is received, no more DbusException messages
are leaked to the end user (LP: #690305).
* User can now subcribe and unsubscribe from folders (LP: #689646).
* Dbus booleans are now those strings whose bool() defines its value. So,
'' for False and any other non empty string for True (LP: #683619).
* File sync status is retrieved and displayed in the right top corner
(LP: #673670).
* Adding handling for file sync disabled (only backend for now).
* Management panel is not twined itself if CredentialsFound signal is
received several times (LP: #683649).
[ Rodney Dawes <email address hidden> ]
* Default to None and initialize if None in code, instead of mutable
defaults.
-- Natalia Bidart (nessita) <email address hidden> Wed, 22 Dec 2010 11:15:04 -0300