Focus on terminator window not enough to drop URGENT

Bug #600280 reported by Jani Uusitalo on 2010-06-30
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Terminator
Medium
Unassigned
terminator (Ubuntu)
Undecided
Unassigned

Bug Description

Binary package hint: terminator

I'm in a system running the Netbook Environment, an up-to-date Lucid. In terminator's settings, I have 'Terminal bell' set to be shown as 'Window list flash'. This goes nicely together with irssi (which I'm running through ssh on a remote server) being set to ring the bell on messages I want to be informed of.

However, when the window list is flashing, and I bring the terminator window on top, it doesn't clear the "URGENT" — i.e. the window list keeps on flashing. Furthermore, in a split terminator window, if I left-click on the segment running irssi, which raised the "URGENT", the flashing still won't stop. I have to type something into the terminal to make the flashing stop.

I'm not too familiar with the inner workings and relations between the different signals involved in here, but I presume the flashing should stop when the window with "URGENT" is activated, or brought on top, or at least when the segment in question is activated (or left-clicked).

Steps to reproduce:
1. Set 'Terminal bell' to make 'Window list flash' in terminator's settings.
2. Run an app that rings the terminal bell in terminator after a while.
3. De-activate terminator's window (bring another app on top) and wait for the bell.
4. When terminator flashes in window list, activate it.

Expected result:
Terminator's flashing in the window list stops.

Actual result:
Terminator keeps flashing in the window list until I type something into its window.

Related branches

Chris Jones (cmsj) on 2010-07-01
Changed in terminator (Ubuntu):
status: New → Confirmed
Changed in terminator:
status: New → Triaged
milestone: none → 0.94
importance: Undecided → Medium
Chris Jones (cmsj) wrote :

Revisions 1053 and 1054 on trunk should fix this - the urgency hint will now be cleared on any mouse click event on the window, or by the window gaining focus.

Changed in terminator:
status: Triaged → Fix Committed
Chris Jones (cmsj) on 2010-07-03
Changed in terminator (Ubuntu):
status: Confirmed → In Progress
Chris Jones (cmsj) on 2010-07-14
Changed in terminator:
status: Fix Committed → Fix Released
Chris Jones (cmsj) on 2010-09-20
Changed in terminator (Ubuntu):
status: In Progress → Fix Released