org.freedesktop.login1.PowerOff() call doesnt work

Bug #1172105 reported by Tim Lunn
10
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Ubuntu GNOME
New
Undecided
Unassigned
systemd (Ubuntu)
New
Undecided
Unassigned

Bug Description

org.freedesktop.login1.PowerOff() call doesnt work currently, it fails with

systemd-logind[1205]: execute_shutdown_or_sleep: failed to call org.freedesktop.systemd1, using fallback: Unknown unit: poweroff.target

 it seems that the unitname for this action is actually 'poweroff.target'

ProblemType: Bug
DistroRelease: Ubuntu 13.04
Package: libsystemd-login0 198-0ubuntu11
ProcVersionSignature: Ubuntu 3.8.0-19.29-generic 3.8.8
Uname: Linux 3.8.0-19-generic x86_64
NonfreeKernelModules: nvidia
ApportVersion: 2.9.2-0ubuntu8
Architecture: amd64
Date: Wed Apr 24 13:06:46 2013
InstallationDate: Installed on 2012-09-23 (213 days ago)
InstallationMedia: Ubuntu GNOME Remix 12.10 "Quantal Quetzal" - Alpha amd64(20120922)
MarkForUpload: True
SourcePackage: systemd
UpgradeStatus: No upgrade log present (probably fresh install)

Revision history for this message
Tim Lunn (darkxst) wrote :
Revision history for this message
Tim Lunn (darkxst) wrote :
Revision history for this message
Ubuntu Foundations Team Bug Bot (crichton) wrote :

The attachment "update unitname for poweroff target" seems to be a debdiff. The ubuntu-sponsors team has been subscribed to the bug report so that they can review and hopefully sponsor the debdiff. If the attachment isn't a patch, please remove the "patch" flag from the attachment, remove the "patch" tag, and if you are member of the ~ubuntu-sponsors, unsubscribe the team.

[This is an automated message performed by a Launchpad user owned by ~brian-murray, for any issue please contact him.]

tags: added: patch
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.