Backport automount fix into Bionic

Bug #1762433 reported by Rik Mills
14
This bug affects 2 people
Affects Status Importance Assigned to Milestone
plasma-desktop (Ubuntu)
Invalid
Medium
Unassigned
Bionic
Invalid
Medium
Unassigned
solid (Ubuntu)
Invalid
Medium
Unassigned
Bionic
Invalid
Medium
Unassigned

Bug Description

Previous fix for an automount regression in 5.44 has itself caused a regression for automounting internal volumes.

https://bugs.kde.org/show_bug.cgi?id=391706

See also: https://phabricator.kde.org/T8471

Required fixes:

Frameworks: 5.44 or 5.45 with: https://cgit.kde.org/solid.git/commit/?id=122a6cd8989a4bd3096fddea908a1c2b223be62a

Plasma 5.12.x with: https://cgit.kde.org/plasma-desktop.git/commit/?id=8dedbcdf4197eccd5e06c18a66a63d15615c8171

Rik Mills (rikmills)
Changed in plasma-desktop (Ubuntu Bionic):
importance: Undecided → Medium
Changed in solid (Ubuntu Bionic):
importance: Undecided → Medium
Changed in plasma-desktop (Ubuntu Bionic):
milestone: none → ubuntu-18.04
Changed in solid (Ubuntu Bionic):
milestone: none → ubuntu-18.04
Revision history for this message
Nate Graham (pointedstick) wrote :

That fix didn't work. We now have a new, actually working fix that can be backported, which is tracked by https://bugs.launchpad.net/ubuntu/+source/solid/+bug/1789292

Changed in solid (Ubuntu):
status: New → Invalid
Changed in solid (Ubuntu Bionic):
status: New → Invalid
Changed in plasma-desktop (Ubuntu Bionic):
status: New → Invalid
Changed in plasma-desktop (Ubuntu):
status: New → Invalid
To post a comment you must log in.