root@cerebro:~# upsd -DDD Network UPS Tools upsd 2.6.0 0.000000 listen_add: added 127.0.0.1:3493 0.000217 setuptcp: try to bind to 127.0.0.1 port 3493 0.000546 listening on 127.0.0.1 port 3493 0.001170 Can't connect to UPS [powercom] (usbhid-ups-powercom): No such file or directory 0.002436 allowfrom in upsd.users is no longer used 0.002597 mainloop: polling 1 filedescriptors 2.003888 mainloop: no data available 2.003989 mainloop: polling 1 filedescriptors 4.005913 mainloop: no data available 4.006008 mainloop: polling 1 filedescriptors 6.008193 mainloop: no data available 6.008303 mainloop: polling 1 filedescriptors 8.008539 mainloop: no data available 8.008664 mainloop: polling 1 filedescriptors 10.010710 mainloop: no data available 10.010810 mainloop: polling 1 filedescriptors 12.011850 mainloop: no data available 12.011969 mainloop: polling 1 filedescriptors 14.013886 mainloop: no data available 14.014027 mainloop: polling 1 filedescriptors 16.014881 mainloop: no data available 16.015012 mainloop: polling 1 filedescriptors 18.017058 mainloop: no data available 18.017172 Connected to UPS [powercom]: usbhid-ups-powercom 18.017204 mainloop: polling 1 filedescriptors 20.019265 mainloop: no data available 20.019325 mainloop: polling 2 filedescriptors 20.019441 mainloop: polling 2 filedescriptors 20.019542 mainloop: polling 2 filedescriptors 20.019615 mainloop: polling 2 filedescriptors 20.019650 UPS [powercom]: dump is done 20.019667 mainloop: polling 2 filedescriptors 22.020887 mainloop: no data available 22.020958 mainloop: polling 2 filedescriptors 24.022881 mainloop: no data available 24.022941 mainloop: polling 2 filedescriptors 25.768442 Connect from 127.0.0.1 25.768503 Pinging UPS [powercom] 25.768533 mainloop: polling 3 filedescriptors 25.768602 write: [destfd=6] [len=24] [BEGIN LIST VAR powercom] 25.768648 write: [destfd=6] [len=34] [VAR powercom battery.charge "100"] 25.768691 write: [destfd=6] [len=37] [VAR powercom battery.charge.low "10"] 25.768733 write: [destfd=6] [len=41] [VAR powercom battery.charge.warning "30"] 25.768775 write: [destfd=6] [len=39] [VAR powercom battery.date "2009/12/23"] 25.768816 write: [destfd=6] [len=37] [VAR powercom battery.runtime "25600"] 25.768861 write: [destfd=6] [len=35] [VAR powercom battery.type "PbAc "] 25.768914 write: [destfd=6] [len=43] [VAR powercom device.mfr "POWERCOM Co.,LTD"] 25.768958 write: [destfd=6] [len=44] [VAR powercom device.model "HID UPS Battery"] 25.768999 write: [destfd=6] [len=42] [VAR powercom device.serial "004-0D9F-000"] 25.769041 write: [destfd=6] [len=31] [VAR powercom device.type "ups"] 25.769082 write: [destfd=6] [len=38] [VAR powercom driver.name "usbhid-ups"] 25.769122 write: [destfd=6] [len=44] [VAR powercom driver.parameter.pollfreq "30"] 25.769164 write: [destfd=6] [len=47] [VAR powercom driver.parameter.pollinterval "2"] 25.769205 write: [destfd=6] [len=54] [VAR powercom driver.parameter.port "/dev/usb/hiddev0"] 25.769246 write: [destfd=6] [len=47] [VAR powercom driver.parameter.productid "0004"] 25.769283 write: [destfd=6] [len=36] [VAR powercom driver.version "2.6.0"] 25.769312 write: [destfd=6] [len=52] [VAR powercom driver.version.data "PowerCOM HID 0.2"] 25.769339 write: [destfd=6] [len=44] [VAR powercom driver.version.internal "0.35"] 25.769393 write: [destfd=6] [len=36] [VAR powercom input.frequency "50.0"] 25.769430 write: [destfd=6] [len=35] [VAR powercom input.voltage "224.0"] 25.769458 write: [destfd=6] [len=41] [VAR powercom input.voltage.nominal "220"] 25.769485 write: [destfd=6] [len=37] [VAR powercom output.frequency "50.0"] 25.769512 write: [destfd=6] [len=36] [VAR powercom output.voltage "224.0"] 25.769538 write: [destfd=6] [len=42] [VAR powercom output.voltage.nominal "220"] 25.769567 write: [destfd=6] [len=41] [VAR powercom ups.beeper.status "enabled"] 25.769593 write: [destfd=6] [len=35] [VAR powercom ups.date "2009/12/23"] 25.769620 write: [destfd=6] [len=37] [VAR powercom ups.delay.shutdown "20"] 25.769646 write: [destfd=6] [len=34] [VAR powercom ups.delay.start "60"] 25.769672 write: [destfd=6] [len=26] [VAR powercom ups.load "9"] 25.769698 write: [destfd=6] [len=40] [VAR powercom ups.mfr "POWERCOM Co.,LTD"] 25.769725 write: [destfd=6] [len=41] [VAR powercom ups.model "HID UPS Battery"] 25.769752 write: [destfd=6] [len=34] [VAR powercom ups.productid "0004"] 25.769778 write: [destfd=6] [len=39] [VAR powercom ups.serial "004-0D9F-000"] 25.769805 write: [destfd=6] [len=29] [VAR powercom ups.status "OL"] 25.769831 write: [destfd=6] [len=47] [VAR powercom ups.test.result "Done and passed"] 25.770590 write: [destfd=6] [len=36] [VAR powercom ups.timer.shutdown "0"] 25.770626 write() failed for 127.0.0.1: Broken pipe 25.770650 Disconnect from 127.0.0.1 25.770690 mainloop: polling 2 filedescriptors 25.828466 Got PONG from UPS [powercom] 25.828517 mainloop: polling 2 filedescriptors 27.830563 mainloop: no data available 27.830626 mainloop: polling 2 filedescriptors 29.352118 mainloop: polling 1 filedescriptors 31.353887 mainloop: no data available 31.353991 mainloop: polling 1 filedescriptors 32.964926 mainloop: Interrupted system call 32.964984 Signal 2: exiting