Bus 004 Device 003: ID 0bdb:1900 Ericsson Business Mobile Networks BV Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.00 bDeviceClass 2 Communications bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x0bdb Ericsson Business Mobile Networks BV idProduct 0x1900 bcdDevice 0.00 iManufacturer 1 Ericsson iProduct 2 Ericsson F3507g Mobile Broadband Minicard Composite Device iSerial 3 0115650002335270 bNumConfigurations 2 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 392 bNumInterfaces 11 bConfigurationValue 1 iConfiguration 4 WMC Device bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 20mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 0 bInterfaceClass 2 Communications bInterfaceSubClass 8 Wireless Handset Control bInterfaceProtocol 0 iInterface 5 S_WHCM CDC Header: bcdCDC 1.10 CDC WHCM: bcdVersion 1.00 CDC Union: bMasterInterface 0 bSlaveInterface 1 2 3 4 5 6 7 8 9 10 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 2 Abstract (modem) bInterfaceProtocol 1 AT-commands (v.25ter) iInterface 6 Ericsson F3507g Mobile Broadband Minicard Modem CDC Header: bcdCDC 1.10 CDC Union: bMasterInterface 1 bSlaveInterface 2 CDC Call Management: bmCapabilities 0x03 call management use DataInterface bDataInterface 2 CDC ACM: bmCapabilities 0x07 sends break line coding and serial state get/set/clear comm features Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x8a EP 10 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 2 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 7 Ericsson F3507g Mobile Broadband Minicard Modem Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x01 EP 1 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 3 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 2 Abstract (modem) bInterfaceProtocol 1 AT-commands (v.25ter) iInterface 8 Ericsson F3507g Mobile Broadband Minicard Data Modem CDC Header: bcdCDC 1.10 CDC Union: bMasterInterface 3 bSlaveInterface 4 CDC Call Management: bmCapabilities 0x03 call management use DataInterface bDataInterface 4 CDC ACM: bmCapabilities 0x07 sends break line coding and serial state get/set/clear comm features Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x89 EP 9 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 4 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 9 Ericsson F3507g Mobile Broadband Minicard Data Modem Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 5 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 9 Device Management bInterfaceProtocol 1 iInterface 10 Ericsson F3507g Mobile Broadband Minicard Device Management CDC Header: bcdCDC 1.10 CDC Device Management: bcdVersion 1.00 wMaxCommand 2048 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x8b EP 11 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 6 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 9 Device Management bInterfaceProtocol 1 iInterface 11 Ericsson F3507g Mobile Broadband Minicard PC SC Port CDC Header: bcdCDC 1.10 CDC Device Management: bcdVersion 1.00 wMaxCommand 2048 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x8c EP 12 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 7 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 10 Mobile Direct Line bInterfaceProtocol 0 iInterface 12 Ericsson F3507g Mobile Broadband Minicard Network Adapter CDC Header: bcdCDC 1.10 CDC MDLM: bcdCDC 1.00 bGUID {a317a88b-045e-4f01-a607-c0ffcb7e392a} CDC MDLM detail: bGuidDescriptorType 00 bDetailData 02 CDC Union: bMasterInterface 7 bSlaveInterface 8 CDC Ethernet: iMacAddress 13 028037EC0200 bmEthernetStatistics 0x00000000 wMaxSegmentSize 1514 wNumberMCFilters 0x8040 bNumberPowerFilters 1 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x87 EP 7 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 7 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 8 bAlternateSetting 0 bNumEndpoints 0 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 14 Ericsson F3507g Mobile Broadband Minicard Network Adapter Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 8 bAlternateSetting 1 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 15 - Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x04 EP 4 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x84 EP 4 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 8 bAlternateSetting 2 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 238 iInterface 16 - Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x04 EP 4 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x84 EP 4 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 9 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 2 Abstract (modem) bInterfaceProtocol 1 AT-commands (v.25ter) iInterface 17 Ericsson F3507g Mobile Broadband Minicard GPS Port CDC Header: bcdCDC 1.10 CDC Union: bMasterInterface 9 bSlaveInterface 10 CDC Call Management: bmCapabilities 0x03 call management use DataInterface bDataInterface 12 CDC ACM: bmCapabilities 0x07 sends break line coding and serial state get/set/clear comm features Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x85 EP 5 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 10 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 18 Ericsson F3507g Mobile Broadband Minicard GPS Port Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x06 EP 6 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x86 EP 6 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 332 bNumInterfaces 9 bConfigurationValue 2 iConfiguration 4 WMC Device bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 20mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 0 bInterfaceClass 2 Communications bInterfaceSubClass 8 Wireless Handset Control bInterfaceProtocol 0 iInterface 5 S_WHCM CDC Header: bcdCDC 1.10 CDC WHCM: bcdVersion 1.00 CDC Union: bMasterInterface 0 bSlaveInterface 1 2 3 4 5 6 7 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 2 Abstract (modem) bInterfaceProtocol 1 AT-commands (v.25ter) iInterface 6 Ericsson F3507g Mobile Broadband Minicard Modem CDC Header: bcdCDC 1.10 CDC Union: bMasterInterface 1 bSlaveInterface 2 CDC Call Management: bmCapabilities 0x03 call management use DataInterface bDataInterface 2 CDC ACM: bmCapabilities 0x07 sends break line coding and serial state get/set/clear comm features Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x8a EP 10 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 2 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 7 Ericsson F3507g Mobile Broadband Minicard Modem Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x01 EP 1 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 3 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 2 Abstract (modem) bInterfaceProtocol 1 AT-commands (v.25ter) iInterface 8 Ericsson F3507g Mobile Broadband Minicard Data Modem CDC Header: bcdCDC 1.10 CDC Union: bMasterInterface 3 bSlaveInterface 4 CDC Call Management: bmCapabilities 0x03 call management use DataInterface bDataInterface 4 CDC ACM: bmCapabilities 0x07 sends break line coding and serial state get/set/clear comm features Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x89 EP 9 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 4 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 9 Ericsson F3507g Mobile Broadband Minicard Data Modem Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 5 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 9 Device Management bInterfaceProtocol 1 iInterface 10 Ericsson F3507g Mobile Broadband Minicard Device Management CDC Header: bcdCDC 1.10 CDC Device Management: bcdVersion 1.00 wMaxCommand 2048 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x8b EP 11 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 6 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 9 Device Management bInterfaceProtocol 1 iInterface 11 Ericsson F3507g Mobile Broadband Minicard PC SC Port CDC Header: bcdCDC 1.10 CDC Device Management: bcdVersion 1.00 wMaxCommand 2048 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x8c EP 12 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 8 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 7 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 2 Communications bInterfaceSubClass 10 Mobile Direct Line bInterfaceProtocol 0 iInterface 12 Ericsson F3507g Mobile Broadband Minicard Network Adapter CDC Header: bcdCDC 1.10 CDC MDLM: bcdCDC 1.00 bGUID {a317a88b-045e-4f01-a607-c0ffcb7e392a} CDC MDLM detail: bGuidDescriptorType 00 bDetailData 02 CDC Union: bMasterInterface 7 bSlaveInterface 8 CDC Ethernet: iMacAddress 13 028037EC0200 bmEthernetStatistics 0x00000000 wMaxSegmentSize 1514 wNumberMCFilters 0x8040 bNumberPowerFilters 1 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x87 EP 7 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 7 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 8 bAlternateSetting 0 bNumEndpoints 0 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 14 Ericsson F3507g Mobile Broadband Minicard Network Adapter Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 8 bAlternateSetting 1 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 0 iInterface 15 - Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x04 EP 4 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x84 EP 4 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 8 bAlternateSetting 2 bNumEndpoints 2 bInterfaceClass 10 CDC Data bInterfaceSubClass 0 Unused bInterfaceProtocol 238 iInterface 16 - Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x04 EP 4 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x84 EP 4 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.00 bDeviceClass 2 Communications bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 2 Device Status: 0x0000 (Bus Powered)