natacpi bug in 4.18.0-16-generic, fixed upstream 5.0.2
Bug #1820796 reported by
Tim Richardson
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
linux (Ubuntu) |
Fix Committed
|
Undecided
|
Unassigned |
Bug Description
low-impact bug, easy workaround.
Thinkpad T480
4.18.0-16-generic
Bug:
# cd /sys/class/
#
# echo 95 > charge_
bash: echo: write error: No such device
but it works for BAT0
It means tlp, latest version installed via PPA, by default can't set battery charge thresholds for the second battery in ubuntu 18.04 because tlp now defaults to using natacpi.
This can be reverted to the old way of working via a simple change in the tlp conf file.
This bug is fixed in 5.0.2 installed from ubuntu mainline ppa. I did not try earlier.
-----