[vios] install fails on Power8 (biot)

Bug #1812924 reported by Manoj Iyer
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
The Ubuntu-power-systems project
Won't Fix
High
bugproxy

Bug Description

I am trying to install vios on our Power8 system Biot, and it is failing as follows:

nimol_config MESSAGE: Processing multivolume 2...
/bin/cat: /mnt/nimol/nimol/ioserver_res/mksysb: Input/output error
nimol_config ERROR: error from command /bin/cat /mnt/nimol/nimol/ioserver_res/mksysb >> /extra/default1/mksysb

The vios images I have are:
PVM_VIRTUAL_IO_SBI_v2.2.6.20_1OF2.iso and PVM_VIRTUAL_IO_SBI_v2.2.6.20_2OF2.iso

Could it be that the VIOS image that I have might be the issue? If that is the case would it be possible for me to get the latest VIOS image?

== detailed output from installios ==

hscroot@cichus:~> installios
Logging session output to /tmp/installios.28853.log.

The following objects of type "managed system" were found. Please select one:

1. biot-Server-8408-E8E-SN10A799V

Enter a number: 1

The following objects of type "virtual I/O server partition" were found. Please select one:

1. biotv1
2. biotvios1

Enter a number (1-2): 2

The following objects of type "profile" were found. Please select one:

1. biotvios1_profile

Enter a number: 1
Enter the source of the installation images [/dev/cdrom]: /extra/viosimages/default1/dvdimage.v1.iso
Enter the client's intended IP address: 10.245.64.125
Enter the client's intended subnet mask: 255.255.255.0
Enter the client's gateway: 10.245.64.1
(Note: To use the adapter's default setting, enter 'default' for speed)
Enter the client's speed [100]: 100
Enter the client's duplex [full]: full
Enter the numeric VLAN tag priority for the client (0 to 7), 0=none [0]:
Enter the numeric VLAN tag identifier for the client (0 to 4094), 0=none [0]:
Would you like to configure the client's network after the installation [yes]/no? yes
Please select an adapter you would like to use for this installation.
(WARNING: The client IP address must be reachable through this adapter!
1. eth0
2. eth1
3. eth2
4. eth3
Enter a number (1-4): 1

Retrieving information for available network adapters
This will take several minutes...

The following objects of type "ethernet adapters" were found. Please select one:

1. ent U78C7.001.RCH0089-P1-C11-T1 40f2e95dbe68 /pci@800000020000018/ethernet@0 n/a physical
2. ent U78C7.001.RCH0089-P1-C11-T2 40f2e95dbe69 /pci@800000020000018/ethernet@0,1 n/a physical
3. ent U78C7.001.RCH0089-P1-C11-T3 40f2e95dbe6a /pci@800000020000018/ethernet@0,2 n/a physical
4. ent U78C7.001.RCH0089-P1-C11-T4 40f2e95dbe6b /pci@800000020000018/ethernet@0,3 n/a physical

Enter a number (1-4): 1
Here are the values you entered:

managed system = biot-Server-8408-E8E-SN10A799V
virtual I/O server partition = biotvios1
profile = biotvios1_profile
source = /extra/viosimages/default1/dvdimage.v1.iso
IP address = 10.245.64.125
subnet mask = 255.255.255.0
gateway = 10.245.64.1
speed = 100
duplex = full
configure network = yes
install interface = eth0
ethernet adapters = 40:f2:e9:5d:be:68

Press enter to proceed or type Ctrl-C to cancel...

nimol_config MESSAGE: Added "REMOTE_ACCESS_METHOD /usr/bin/rsh" to the file "/etc/nimol.conf"
nimol_config MESSAGE: Removed "disable = yes" from the file "/etc/xinetd.d/tftp"
nimol_config MESSAGE: Added "disable = no" to the file "/etc/xinetd.d/tftp"
nimol_config MESSAGE: Removed "SYSLOGD_OPTIONS=" from the file "/etc/sysconfig/rsyslog"
nimol_config MESSAGE: Added "SYSLOGD_OPTIONS=-r " to the file "/etc/sysconfig/rsyslog"
nimol_config MESSAGE: Removed "local2,local3.* -/var/log/localmessages;RSYSLOG_TraditionalFileFormat" from the file "/etc/rsyslog.conf"
nimol_config MESSAGE: Added "local3.* -/var/log/localmessages;RSYSLOG_TraditionalFileFormat" to the file "/etc/rsyslog.conf"
nimol_config MESSAGE: Added "local2.* /var/log/nimol.log" to the file "/etc/rsyslog.conf"
nimol_config MESSAGE: Executed /usr/sbin/nimol_bootreplyd -l -d -f /etc/nimoltab -s 192.168.220.188.
nimol_config MESSAGE: Successfully configured NIMOL.
nimol_config MESSAGE: target directory: /extra/default1
nimol_config MESSAGE: source directory: /mnt/nimol
nimol_config MESSAGE: Copying /mnt/nimol/nimol/ioserver_res/booti.chrp.mp.ent.Z to /extra/default1...
nimol_config MESSAGE: Copying /mnt/nimol/nimol/ioserver_res/ispot.tar.Z to /extra/default1...
nimol_config MESSAGE: Copying /mnt/nimol/nimol/ioserver_res/mksysb to /extra/default1/mksysb...
nimol_config MESSAGE: Processing multivolume 1...
nimol_config MESSAGE: Please insert volume 2 to continue.
nimol_config MESSAGE: Found volume 2, continuing ...
nimol_config MESSAGE: Processing multivolume 2...
/bin/cat: /mnt/nimol/nimol/ioserver_res/mksysb: Input/output error
nimol_config ERROR: error from command /bin/cat /mnt/nimol/nimol/ioserver_res/mksysb >> /extra/default1/mksysb
nimol_config MESSAGE: Running undo...
nimol_config MESSAGE: Executed kill 32476.
nimol_config MESSAGE: Removed /extra/default1/booti.chrp.mp.ent.
nimol_config MESSAGE: Removed /tftpboot/default1.chrp.mp.ent.
nimol_config MESSAGE: Removed {TARGET_DIR}/SPOT.
nimol_config MESSAGE: Removed /extra/default1.
ERROR from nimol_config.
Label exists in configuration file and must be removed first.
hscroot@cichus:~>

bugproxy (bugproxy)
tags: added: architecture-ppc64le bugnameltc-174894 severity-high targetmilestone-inin---
Revision history for this message
bugproxy (bugproxy) wrote : Comment bridged from LTC Bugzilla

------- Comment From <email address hidden> 2019-01-24 09:35 EDT-------
<Note by aix, 2019/01/24 08:33:19 seq: 2 rel: 0 action: note>
Defect 1075668 was opened with a phaseFound value of 'unknown',
please use the Defect -modify command to update the phaseFound field when the proper phase is known. The
defect will not be able to move to the Verify state until the phaseFound field is updated.

Revision history for this message
bugproxy (bugproxy) wrote :

------- Comment From <email address hidden> 2019-01-28 06:55 EDT-------
<Note by prabhmur, 2019/01/28 05:49:04 seq: 6 rel: 0 action: assign>
We are hitting the issue on below code.

+1 #!/bin/ksh
+2 # IBM_PROLOG_BEGIN_TAG
+3 # This is an automatically generated prolog.
+4 #
+5 # bos72L src/bos/usr/lib/nim/methods/installios.sh 1.23.1.8

+2442 /usr/bin/cat ${SOURCE_MKSYSB} >> ${TARGET_DIR_MKSYSB}/${CLIENT_MKSYSB}
+2443 if [[ $? -ne 0 ]]; then
+2444 /usr/bin/dspmsg -s ${MSG_SET} cmdnim.cat ${MSG_FAILED} 'failed\n' \
+2445 | /usr/bin/tee -a ${INSTALLIOS_LOG}
+2446 /usr/bin/dspmsg -s ${ERR_SET} cmdnim.cat ${ERR_UNABLE_COPY_FROM_TO} \
+2447 '%1$s: Unable to copy from %2$s to %3$s.\n' \
+2448 "${PROGRAM}" "${SYSB_FILE}" "${TARGET_DIR_MKSYSB}" \
+2449 | /usr/bin/tee -a ${INSTALLIOS_LOG}
+2450 return 1
+2451 fi

Asssigning to cmdnim to take a look.

Manoj Iyer (manjo)
Changed in ubuntu-power-systems:
status: New → Won't Fix
Revision history for this message
bugproxy (bugproxy) wrote :

------- Comment From <email address hidden> 2019-01-29 14:25 EDT-------
<Note by pfinley, 2019/01/29 13:16:36 seq: 7 rel: 0 action: note>
This is an error from the cat command on the HMC. The defect
should be inspected by hmcscreen or by installios dev. AIX team
no longer screens defects for installios/HMC.