Change octavia::health_manager::event_streamer_driver default to noop_event_streamer

Bug #1787608 reported by Carlos Goncalves
10
This bug affects 2 people
Affects Status Importance Assigned to Milestone
tripleo
Fix Released
Medium
Carlos Goncalves

Bug Description

tripleo-heat-templates forces octavia::health_manager::event_streamer_driver to be set to 'queue_event_streamer' with no option to change it. The event streamer specifies which driver to use for syncing Octavia and Neutron LBaaS databases. It is highly recommended to disable if one doesn't need to sync the database or is running Octavia in standalone mode by setting event_streamer_driver to noop_event_streamer.

See also: https://bugzilla.redhat.com/show_bug.cgi?id=1618772

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to tripleo-heat-templates (master)

Fix proposed to branch: master
Review: https://review.openstack.org/593083

Changed in tripleo:
assignee: nobody → Carlos Goncalves (cgoncalves)
status: New → In Progress
tags: added: rocky-backport-potential
tags: added: queens-backport-potential
Changed in tripleo:
milestone: none → rocky-rc1
importance: Undecided → Medium
Changed in tripleo:
milestone: rocky-rc1 → stein-1
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to tripleo-heat-templates (master)

Reviewed: https://review.openstack.org/593083
Committed: https://git.openstack.org/cgit/openstack/tripleo-heat-templates/commit/?id=e066722d27672c6d781c71b6a07acef50b9821a6
Submitter: Zuul
Branch: master

commit e066722d27672c6d781c71b6a07acef50b9821a6
Author: Carlos Goncalves <email address hidden>
Date: Fri Aug 17 17:32:19 2018 +0200

    Add OctaviaEventStreamerDriver and change default

    octavia::health_manager::event_streamer_driver is forcely set to
    'queue_event_streamer' with no option to change it. The event streamer
    specifies which driver to use for syncing Octavia and Neutron LBaaS
    databases. It is highly recommended to disable if one doesn't need to
    sync the database or is running Octavia in standalone mode by setting
    event_streamer_driver to noop_event_streamer.

    Change-Id: I400ce9a059aba195cdd987ba51360ef3d7f258f3
    Closes-Bug: #1787608

Changed in tripleo:
status: In Progress → Fix Released
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to tripleo-heat-templates (stable/rocky)

Fix proposed to branch: stable/rocky
Review: https://review.openstack.org/598240

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to tripleo-heat-templates (stable/queens)

Fix proposed to branch: stable/queens
Review: https://review.openstack.org/598241

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/tripleo-heat-templates 10.0.0

This issue was fixed in the openstack/tripleo-heat-templates 10.0.0 release.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to tripleo-heat-templates (stable/queens)

Reviewed: https://review.openstack.org/598241
Committed: https://git.openstack.org/cgit/openstack/tripleo-heat-templates/commit/?id=023dc2ebb471822fcd7b0044ddcc04b6bcc8a96d
Submitter: Zuul
Branch: stable/queens

commit 023dc2ebb471822fcd7b0044ddcc04b6bcc8a96d
Author: Carlos Goncalves <email address hidden>
Date: Fri Aug 17 17:32:19 2018 +0200

    Add OctaviaEventStreamerDriver and change default

    octavia::health_manager::event_streamer_driver is forcely set to
    'queue_event_streamer' with no option to change it. The event streamer
    specifies which driver to use for syncing Octavia and Neutron LBaaS
    databases. It is highly recommended to disable if one doesn't need to
    sync the database or is running Octavia in standalone mode by setting
    event_streamer_driver to noop_event_streamer.

    Change-Id: I400ce9a059aba195cdd987ba51360ef3d7f258f3
    Closes-Bug: #1787608
    (cherry picked from commit e066722d27672c6d781c71b6a07acef50b9821a6)

tags: added: in-stable-queens
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to tripleo-heat-templates (stable/rocky)

Reviewed: https://review.openstack.org/598240
Committed: https://git.openstack.org/cgit/openstack/tripleo-heat-templates/commit/?id=8d2085f3c2ea3b6ef00c60246e580d62e74b7cb0
Submitter: Zuul
Branch: stable/rocky

commit 8d2085f3c2ea3b6ef00c60246e580d62e74b7cb0
Author: Carlos Goncalves <email address hidden>
Date: Fri Aug 17 17:32:19 2018 +0200

    Add OctaviaEventStreamerDriver and change default

    octavia::health_manager::event_streamer_driver is forcely set to
    'queue_event_streamer' with no option to change it. The event streamer
    specifies which driver to use for syncing Octavia and Neutron LBaaS
    databases. It is highly recommended to disable if one doesn't need to
    sync the database or is running Octavia in standalone mode by setting
    event_streamer_driver to noop_event_streamer.

    Change-Id: I400ce9a059aba195cdd987ba51360ef3d7f258f3
    Closes-Bug: #1787608
    (cherry picked from commit e066722d27672c6d781c71b6a07acef50b9821a6)

tags: added: in-stable-rocky
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/tripleo-heat-templates 9.2.0

This issue was fixed in the openstack/tripleo-heat-templates 9.2.0 release.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix included in openstack/tripleo-heat-templates 8.3.0

This issue was fixed in the openstack/tripleo-heat-templates 8.3.0 release.

To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.