Unable to set warm-up time

Bug #630161 reported by Bram Bonné
22
This bug affects 4 people
Affects Status Importance Assigned to Milestone
Simple Scan
Triaged
Medium
Unassigned

Bug Description

When trying to scan from within simple scan with the epson perfection 1250, it will only light the lamp and make a short sound.

This problem doesn't occur in XSane if the lamp warmup time is set to >= 5. If the lamp warmup time is < in XSane, it gives the same problem.

The solution is probably just a simple configuration parameter that instructs the sane backend to use a warmup time.

Attached is the debug output.

Revision history for this message
Bram Bonné (brambonne) wrote :
Revision history for this message
Robert Ancell (robert-ancell) wrote :

Log shows this driver has a warm-up setting:
** (simple-scan:5339): DEBUG: Option 24: name='warmup-time' title='Warmup-time' type=int size=4 min=-1, max=999, quant=1 cap=soft-select,soft-detect
** (simple-scan:5339): DEBUG: Description: Warmup-time in seconds.

Changed in simple-scan:
status: New → Triaged
importance: Undecided → Medium
summary: - Epson Perfection 1250 doesn't start scanning, while it does scan in
- XSane.
+ Unable to set warm-up time
Revision history for this message
Bram Bonné (brambonne) wrote :

Wouldn't it be better if the warmup time was pre-set instead of user-configurable? We don't want the casual user worrying about a setting for which the value should be known in advance per scanner model.

For example: I didn't know what to do when XSane wouldn't let me scan until I had searched some forums where they told me that I had to change the value of the lamp warmup time. This type of problem shouldn't occur in a program as simple as simple-scan.

Revision history for this message
Robert Ancell (robert-ancell) wrote :

It sounds to me like it should be set in the driver, i.e. if a particular model of scanner requires 5s to warm up, then the minimum value should be 5. I'm leaving this bug open to gague how widespread this problem may be. I find it unlikely that I'll make a change to simple-scan to support this. You can probably work around this by setting the default in /etc/sane.d.

Revision history for this message
Bram Bonné (brambonne) wrote :

OK thanks for the information. I will look into it some more, and eventually report a bug against the driver if the problem is easily solved there.

Revision history for this message
Bram Bonné (brambonne) wrote :

Setting a different warmup time in the .conf effectively solves the problem. Just so people who get here using Google know: the warmup time can be set in /etc/sane.d/plustek.conf sing the line 'option warmup 1'. It seems a warmup time of 1 second is sufficient for this particular scanner model.

Revision history for this message
Thelasko (stever530) wrote :

Thanks for the help Bram! I seem to be having the same issue with my HP 4100C. Changing that warmup time to 120 in plustek.conf seems to have fixed it.

To post a comment you must log in.