Evaluate LocoNet switch response.

Bug #1052646 reported by Rocrail
4
Affects Status Importance Assigned to Milestone
Rocrail
Fix Released
Wishlist
Unassigned

Bug Description

Tags: ib loconet
Revision history for this message
Rocrail (r.j.versluis) wrote :

B0 05 30 7A OPC_SW_REQ
B4 30 00 7B OPC_LONG_ACK -> Intellibox Buffer Full!

LOPC = OPC_SW_REQ & 0x7F = 0x30
ACK1 = 0x00 -> Fail

Changed in rocrail:
status: New → Confirmed
Revision history for this message
Rocrail (r.j.versluis) wrote :

Implemented in revision 3949.
Activate this option before testing:
http://wiki.rocrail.net/doku.php?id=loconet-cs-en#loconet_details_tab
A restart is necessary.

I habe no IB so I could not test; Switches are set directly over LocoNet not by DCC.

Changed in rocrail:
status: Confirmed → Fix Committed
Rocrail (r.j.versluis)
Changed in rocrail:
status: Fix Committed → Fix Released
Revision history for this message
Rocrail (r.j.versluis) wrote :
To post a comment you must log in.