collection-monitor should not crash when it cannot connect to the collection-server

Bug #507253 reported by Chris Wagner on 2010-01-13
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Resonate
Medium
Unassigned

Bug Description

Rather than crash/close, collection-monitor should just continue in its usual loop of sleeping and then rescanning, so all will continue as normal once the collection-server is back up.

Here's the error that gets logged, at present, when the collection-monitor stumbles across this problem:
  collection-monitor shutting down because of error: getAddrInfo: does not exist (Temporary failure in name resolution)

Changed in resonate:
status: New → Confirmed
importance: Undecided → Medium
Chris Wagner (chris-wagner) wrote :

Fixed in revision 769.

Changed in resonate:
status: Confirmed → Fix Committed