When a system is heavily loaded, ovn-controller can take longer than 5 seconds (default probe interval) to reprocess all the flows. In this case, it'll reconnect to Southbound database and will reprocess all flows causing a snowball effect.
We should make this configurable and default to a higher value (30 seconds should be ok).
Changed in puppet-ovn: | |
assignee: | Daniel Alvarez (dalvarezs) → Lucas Alvares Gomes (lucasagomes) |
Changed in puppet-ovn: | |
assignee: | Lucas Alvares Gomes (lucasagomes) → Daniel Alvarez (dalvarezs) |
To post a comment you must log in.
Fix proposed to branch: master /review. openstack. org/639347
Review: https:/