Inspection on Gen9 should get only active MACs

Bug #1812623 reported by Nisha Agarwal
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
proliantutils
Fix Released
Undecided
Unassigned

Bug Description

It is possible to get only the active MACs(i.e. the MACs which are physically connected through cable) using RIS and Redfish. The Gen10 inspection is already fixed to get only the active MACs to ironic. Gen9 needs to be fixed and return only active MACs to ironic.
Gen8 still this is not possible as RIBCL doesnt give the status of the connected MAC as OK unless OS is provisioned and up and running on the system.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to proliantutils (master)

Reviewed: https://review.openstack.org/632039
Committed: https://git.openstack.org/cgit/openstack/proliantutils/commit/?id=7286d7019c53ff55431690e07df02029acd171b2
Submitter: Zuul
Branch: master

commit 7286d7019c53ff55431690e07df02029acd171b2
Author: Nisha Agarwal <email address hidden>
Date: Mon Jan 21 01:00:51 2019 -0800

    Add NIC inspection for Gen9

    This commit adds NIC inspection for Gen9 and just
    gets the MACs which are physically connected through
    a cable.

    Closes-Bug: 1812623
    Change-Id: Ica624aae8f956a2da061801def6ddc43152a5b09

Changed in proliantutils:
status: New → Fix Released