Inspection fails for Gen7 Servers

Bug #1613794 reported by ankit
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
proliantutils
Fix Released
Undecided
Unassigned

Bug Description

Inspection is failing for Gen7 Servers. Failure occurs because proliantutils is not compatible with Gen7 servers.

2016-08-16 16:13:09.145 ERROR ironic.conductor.manager [req-b0af3c29-63f9-43e7-90e6-4e038c6c16d7 None None] Failed to inspect node 0edb132b-db1e-45cb-8337-d251d35e0bc4: Failed to inspect hardware. Reason: Unable to get memory data. Error: Data missing

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to proliantutils (master)

Reviewed: https://review.openstack.org/357134
Committed: https://git.openstack.org/cgit/openstack/proliantutils/commit/?id=a83cde9f9352a7b70f274c1e3fe13ef390e503a7
Submitter: Jenkins
Branch: master

commit a83cde9f9352a7b70f274c1e3fe13ef390e503a7
Author: ankit <email address hidden>
Date: Thu Aug 18 10:58:56 2016 +0000

    Fix Inspection failure in Gen7

    Inspection is failing for Gen7 Servers. Failure occurs because
    proliantutils is not compatible with Gen7 servers.

    This commit adds the Gen7 support in proliantutils.

    Change-Id: Ic3eaa57f3d1606751e5da2320bb4dbdd556f27cc
    Closes-Bug: #1613794

Changed in proliantutils:
status: New → Fix Released