Server network info should fail if device is not connected
Bug #1895048 reported by
Jeff Lane
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Checkbox Provider - Base |
Fix Released
|
Low
|
Jeff Lane |
Bug Description
-------
Category: NETWORK
Interface: ens4f0np0
Product: BCM57414 NetXtreme-E 10Gb/25Gb RDMA Ethernet Controller (BCM957414A4142CC 10Gb/25Gb Ethernet PCIe)
Vendor: Broadcom Inc. and subsidiaries
Driver: bnxt_en
Driver Version: 1.10.0
Path: /devices/
Id: [14e4:16d7]
Subsystem Id: [14e4:1402]
Mac: b0:26:28:62:32:20
Carrier Status: Disconnected
As we need all NICs connected and configured at test time generally, this job should fail if anything shows that the Carrier status is disconnected, to call attention to needing further review.
Related branches
~bladernr/plainbox-provider-checkbox:1895048-fail-on-carrier-disconnected
- Maciej Kisielewski (community): Approve
-
Diff: 63 lines (+19/-1)2 files modifiedbin/network_device_info.py (+18/-0)
units/ethernet/jobs.pxu (+1/-1)
Changed in plainbox-provider-checkbox: | |
status: | In Progress → Fix Committed |
Changed in plainbox-provider-checkbox: | |
status: | Fix Committed → Fix Released |