oslo.config mutate config don't really work when worker!=1

Bug #1636736 reported by Mehdi Abaakouk on 2016-10-26
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
oslo.service
Undecided
Unassigned

Bug Description

Hi,

When the ProcessLauncher uses more than one worker, the mutate config feature doesn't really work as excepted because all children processes got a SIGTERM, when SIGHUP is sent.

Only the master process will see it's configuration mutated, children processes are restarted...

Regards,
sileht

To post a comment you must log in.
This report contains Public information  Edit
Everyone can see this information.