oslo.config mutate config don't really work when worker!=1

Bug #1636736 reported by Mehdi Abaakouk
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
oslo.service
New
Undecided
Unassigned

Bug Description

Hi,

When the ProcessLauncher uses more than one worker, the mutate config feature doesn't really work as excepted because all children processes got a SIGTERM, when SIGHUP is sent.

Only the master process will see it's configuration mutated, children processes are restarted...

Regards,
sileht

To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.