Steam engine: Radiation steam usage

Bug #1987635 reported by Wesley Johnson
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Open Rails
New
Undecided
Unassigned

Bug Description

I have been writing a Linux, C++ train simulator, using ORTS code and data intially and for formats for loading MSTS files. The simulator itself not a copy of ORTS. I am crediting ORTS often in the code, but am also researchng documents and replacing many of the tables, as I am using Kg/meter/joule entirely.

As I go over the code I have been finding what look like errors in the ORTS code.
I shall report these in separate bug reports.

In all the steam loss calculations, it has not be commented on why the heat loss is the
( boiler_steam_heat - boiler_water_heat ) everywhere.
Some places it is proper to retain the water heat, but others it is not.
This is less clear for things like the blower, as to why the water heat is retained.
The blower condenses its output water and injects it back into the tender, or something like that ???
This needs to be documented in the code for each steam device.

File: MSTSSteamLocomotive.cs

Radiation steam loss:
If the steam is condensed back into water the heat in the water would be retained.
Therefore the loss would be proportional to ( boiler_steam_heat - water_heat ) as ORTS has it.
However, there should NOT be any boiler mass lost then. The steam mass is condensed into water mass.
I am not sure if this is actually steam usage (TotalSteamUsageLBpS).

// From ORTS:
// Basic steam radiation losses
RadiationSteamLossLBpS = pS.FrompM((absSpeedMpS == 0.0f) ?
                3.04f : // lb/min at rest
                5.29f); // lb/min moving
BoilerMassLB -= elapsedClockSeconds * RadiationSteamLossLBpS;
BoilerHeatBTU -= elapsedClockSeconds * RadiationSteamLossLBpS * (BoilerSteamHeatBTUpLB - BoilerWaterHeatBTUpLB);
TotalSteamUsageLBpS += RadiationSteamLossLBpS;
BoilerHeatOutBTUpS += RadiationSteamLossLBpS * (BoilerSteamHeatBTUpLB - BoilerWaterHeatBTUpLB);

// From my code (which has the comments I am trying to share)

// The radiation condenses the steam back into water, so the water heat is not lost.
float radiation_heat_loss = radiation_steam_loss * (boiler_steam_heat - boiler_water_heat);
steam_usage_total += radiation_steam_loss;
boiler_output_heat_rate += radiation_heat_loss;
// boiler_mass -= radiation_steam_loss * tick_secs; // boiler mass should be unaffected by recondensation
boiler_heat -= radiation_heat_loss * tick_secs;

Safety valve loss:
The steam is lost from the boiler entirely. It is not condensed back to water, so the heat loss should be the entire steam heat enthapy.

// From ORTS
SafetyValveUsageLBpS = SafetyValveUsage1LBpS + SafetyValveUsage2LBpS + SafetyValveUsage3LBpS + SafetyValveUsage4LBpS; // Sum all the safety valve discharge rates together
BoilerMassLB -= elapsedClockSeconds * SafetyValveUsageLBpS;
BoilerHeatBTU -= elapsedClockSeconds * SafetyValveUsageLBpS * (BoilerSteamHeatBTUpLB - BoilerWaterHeatBTUpLB); // Heat loss due to safety valve
TotalSteamUsageLBpS += SafetyValveUsageLBpS;
BoilerHeatOutBTUpS += SafetyValveUsageLBpS * (BoilerSteamHeatBTUpLB - BoilerWaterHeatBTUpLB); // Heat loss due to safety valve

// From my code

// Rate of steam loss through all safety valves.
safety_valve_steam_loss = (boiler_pressure + ATMOSPHERE_1) * port_accum * safety_valve_port_steam_rate;

// Heat loss due to safety valve
#if 0
// ORTS: this looks wrong
float steam_loss_heat_rate = safety_valve_steam_loss * (boiler_steam_heat - boiler_water_heat);
#else
// Should lose entire steam heat
float steam_loss_heat_rate = safety_valve_steam_loss * boiler_steam_heat; // Heat loss due to safety valve
#endif
// Steam loss through safety valves, update boiler.
steam_usage_total += safety_valve_steam_loss;
boiler_output_heat_rate += steam_loss_heat_rate;
boiler_mass -= safety_valve_steam_loss * tick_secs;
boiler_heat -= steam_loss_heat_rate * tick_secs; // Heat loss due to safety valve

To post a comment you must log in.