AI train with RSW authority delays waiting point execution

Bug #1455973 reported by Carlo Santucci on 2015-05-17
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Open Rails
Undecided
Carlo Santucci

Bug Description

If at start of activity or after a reversal point an AI train gets RSW authority, an in between WP is executed only when the RSW authority disappears, and where the train is at that moment and not where the WP has laid down. This can be seen in the attached modified demo activity, at start of activity on train Shunter2.

Tags: ai Edit Tag help
Carlo Santucci (carlosanit1) wrote :
Changed in or:
assignee: nobody → Carlo Santucci (carlosanit1)
status: New → In Progress
Carlo Santucci (carlosanit1) wrote :

Fixed in x.3088.

Changed in or:
status: In Progress → Fix Committed
James Ross (twpol) on 2015-05-18
Changed in or:
milestone: none → 1.0
James Ross (twpol) on 2015-05-25
Changed in or:
status: Fix Committed → Fix Released