Correct Steam Usage Values

Bug #1454219 reported by Peter Newell on 2015-05-12
8
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Open Rails
Low
Peter Newell

Bug Description

Following a report that locomotives with low grate areas are losing steam pressure, I have identified an issue with the calculation of steam usage by the cylinders. This patch includes some debug code to fault find the problem., which won't be visible to normal users of Open Rails. It is not anticipated that the patch will cause any problems, initial testing supports this assumption.

James Ross (twpol) wrote :

Please can you use conditional compilation for the debugging code? Unless things can be activated as run-time, code should not be compiled in either.

Changed in or:
assignee: nobody → Peter Newell (coals-to-newcastle)
status: New → In Progress
importance: Undecided → Low
James Ross (twpol) on 2015-05-14
Changed in or:
milestone: none → 1.0
Changed in or:
status: In Progress → Fix Committed
James Ross (twpol) on 2015-05-25
Changed in or:
status: Fix Committed → Fix Released