rebuild instance continues to flush old mpath on failure
Bug #1978827 reported by
norman shen
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
OpenStack Compute (nova) |
In Progress
|
Undecided
|
Unassigned |
Bug Description
Description
===========
When rebuilding instance failed due to a potentially problematic cinder API,
then when trying to rebuild again, nova will try to disconnect volume again
although the path has already clearer. It is generally OK for rbd backend, but
it could cause problem for FC san if new volume got attached during two consecutive rebuilds
which could consume the previous lun id.
Environment
============
It could happen for all versions.
To post a comment you must log in.
Fix proposed to branch: master /review. opendev. org/c/openstack /nova/+ /845995