arnold does not reset autoenable date on manual detentions

Bug #1469988 reported by John-Magne Bredal
8
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Network Administration Visualized
Fix Released
High
John-Magne Bredal

Bug Description

The value for autoenable persists after a port has been detained and opened. This means that if a user detains a previously detained port with a value for autoenable without setting a new value for autoenable, it will be reopened on the next run of the autoenable script.

The fact that this port is previously detained or that it has a value for autoenable, is not visible for the user.

The solution here is to remove any value for autoenable when a detention is lifted.

Changed in nav:
assignee: nobody → John-Magne Bredal (john-m-bredal)
milestone: none → 4.3.1
importance: Undecided → High
status: New → Confirmed
Revision history for this message
John-Magne Bredal (john-m-bredal) wrote :
Changed in nav:
status: Confirmed → Fix Committed
Changed in nav:
status: Fix Committed → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches