Click "ESC" to abort calibration, the calibration window doesn't close quickly while need wait 25 seconds

Bug #203412 reported by cathyli
2
Affects Status Importance Assigned to Milestone
Moblin Applets
Fix Released
Medium
ToddBrandt

Bug Description

Description:
-------------
Click "ESC" to abort calibration, the calibration window doesn't close quickly while need wait 25 seconds. Before applets 0.44 version, the window close quickly after click "ESC" key.

Reproduced steps:
-------------
1. Launch touch screen applet from settings
2. After show calibration window, click "ESC" to abort calibration.

Current results:
-------------
In step2, need wait for 25 seconds, the calibration window closed. It will confuse user that click "ESC" key doesn't take effect to abort calibration.

Expected results:
-------------
In step2, the calibration window should close quickly after click "ESC".

cathyli (cathy-li)
Changed in moblin-applets:
assignee: nobody → todd-e-brandt
importance: Undecided → Medium
Revision history for this message
ToddBrandt (todd-e-brandt) wrote :

Fixed in 0.46

    FIX: I accidentally introduced this bug by adding a touch_disconnect
    call to moblin-system-daemon which was intended to discontinue
    the capture_touch call when the user aborts. Unfortunately DBUS
    doesn't allow simultaneous calls, so it sat waiting for capture-touch
    to return. I removed this functionality.

Changed in moblin-applets:
status: New → Fix Committed
Revision history for this message
cathyli (cathy-li) wrote :

Verified in applets 0.49, the issue is fixed, close it.

Changed in moblin-applets:
status: Fix Committed → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.