main EQ parameters from config are applied to the effect as value, not as scaled parameter value (0.0 - 1.0)

Bug #1983764 reported by ronso0
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Mixxx
Fix Committed
High
ronso0

Bug Description

1) select main EQ: graphical EQ
2a) (Mixxx session) close Mixxx, start Mixxx
or
2b) click 'Reset parameter'
= main volume lowered to like 1/3 (VU meters)

2.4-alpha-1245-g828a189b04
2.3 is not affected

Tags: eq preferences
Revision history for this message
ronso0 (ronso0) wrote (last edit ):

so, it seems none of the devs/2.4-alpha users uses the main graphical EQ :p

I noticed this during tonight's session and just couldn't figure what the heck is wrong, until I remembered that in the previous session I used the graphical main EQ to lower the highs a bit and checked the EQ preferences.
I'm really glad this didn't happen during a show...

description: updated
Changed in mixxx:
milestone: none → 2.4.0
ronso0 (ronso0)
summary: - Reset Parameter of main graphical EQ lowers output volume
+ main EQ parameters from config are applied to the effect as value, not
+ as scaled parameter value (0.0 - 1.0)
Changed in mixxx:
status: New → In Progress
assignee: nobody → ronso0 (ronso0)
Revision history for this message
ronso0 (ronso0) wrote :
ronso0 (ronso0)
Changed in mixxx:
status: In Progress → Fix Committed
Revision history for this message
Swiftb0y (swiftb0y) wrote :

Mixxx now uses GitHub for bug tracking. This bug has been migrated to:
https://github.com/mixxxdj/mixxx/issues/10801