collapsed sampler are not analysed on startup, Latenight/Shade

Bug #1801126 reported by Stefan
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Mixxx
Fix Released
Low
Daniel Schürmann

Bug Description

as discussed in https://github.com/mixxxdj/mixxx/pull/1840

In Skin Shade and Latenight on startup not visible Sampler Waveforms are not analysed/displayed correctly.

https://user-images.githubusercontent.com/9455094/47523482-c563a480-d85d-11e8-99bf-7260fb2a68b3.png

Revision history for this message
Stefan (nopeppermint) wrote :

I just found out, that this only happens if you have a headphone or master output configured, if there is no output configured at all, sampler waveforms are loaded all right.

Be (be.ing)
Changed in mixxx:
status: New → Confirmed
importance: Undecided → Low
Changed in mixxx:
assignee: nobody → Daniel Schürmann (daschuer)
milestone: none → 2.1.0
status: Confirmed → In Progress
Revision history for this message
Daniel Schürmann (daschuer) wrote :
RJ Skerry-Ryan (rryan)
Changed in mixxx:
milestone: 2.1.0 → 2.1.6
status: In Progress → Fix Committed
Revision history for this message
Stefan (nopeppermint) wrote :

indeed, fixed, thanks

Changed in mixxx:
status: Fix Committed → Fix Released
Revision history for this message
Swiftb0y (swiftb0y) wrote :

Mixxx now uses GitHub for bug tracking. This bug has been migrated to:
https://github.com/mixxxdj/mixxx/issues/9502

lock status: Metadata changes locked and limited to project staff
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.