Redfish power configuration vanishes after commissioning

Bug #1862102 reported by Adam Beeman
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
MAAS
Fix Released
Medium
Alberto Donato
2.7
Fix Released
Medium
Alberto Donato

Bug Description

I added a new Dell C6420 to MAAS with power type = Redfish. The system commissioned successfully, then immediately went to power state = Error. Revisiting the Configuration tab for the system, it no longer has any power control information.

I tried repeating this with the checkbox to not try to create a new power control user during commissioning, and got the same result from that as well.

Related branches

summary: - [2.7.0~rc3] Redfish power configuration vanishes after commissioning
+ Redfish power configuration vanishes after commissioning
tags: added: ui
Changed in maas:
status: New → Triaged
importance: Undecided → Medium
milestone: none → 2.8.0b1
Alberto Donato (ack)
tags: removed: ui
Revision history for this message
Alberto Donato (ack) wrote :

It seems the issue is the call to store_node_power_parameters() in src/metadataserver/api.py which ends up being called for a request which doesn't contain power parameters.

Alberto Donato (ack)
Changed in maas:
assignee: nobody → Alberto Donato (ack)
status: Triaged → In Progress
Changed in maas:
status: In Progress → Fix Committed
Alberto Donato (ack)
Changed in maas:
status: Fix Committed → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.