Bug Description

While solving LP:1847537 I discovered that factory.make_RackController and factory.make_RegionController were not linking a static IP to created interfaces. I fixed this in the factory with the following patch

diff --git a/src/maasserver/testing/factory.py b/src/maasserver/testing/factory.py
index 59391e6..ef2a825 100644
--- a/src/maasserver/testing/factory.py
+++ b/src/maasserver/testing/factory.py
@@ -1067,6 +1067,10 @@ class Factory(maastesting.factory.Factory):
             NODE_STATUS.NEW,
             NODE_STATUS.COMMISSIONING,
             NODE_STATUS.FAILED_COMMISSIONING,
+ ] or node.node_type in [
+ NODE_TYPE.RACK_CONTROLLER,
+ NODE_TYPE.REGION_CONTROLLER,
+ NODE_TYPE.REGION_AND_RACK_CONTROLLER,
         ]
         if should_have_default_link_configuration:
             self.make_StaticIPAddress(

This causes the following query_count tests to fail:
maasserver.api.tests.test_tag.TestTagAPI.test_GET_rack_controllers_query_count
maasserver.websockets.handlers.tests.test_controller.TestControllerHandler.test_get_num_queries_is_the_expected_number