Malformed input in the IP addr field in "power parameters" causes part of SQL error to be shown

Bug #1839189 reported by Vladimir Grevtsev
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
MAAS
Triaged
High
Unassigned

Bug Description

UI bug video: https://drive.google.com/open?id=1VhewlMQsY-whVvSt1y0R6GxDqr2P7NlZ
MAAS packages: http://paste.ubuntu.com/p/XqMwCN49QM/

Steps to reproduce:

1. Open machine > configuration > power configuration
2. Edit > select IPMI or Intel AMT
3. Enter "123" in both fields, click "Save changes" -> error "Error: invalid input syntax for type inet: "123" LINE 1: ...ype" = 6) AND "maasserver_staticipaddress"."ip" = '123'::ine... ^"
4. Enter "1231231231" -> same as in #3
5. "12312312312" -> Error: failed to detect a valid IP address from '12312312312' (as expected in all of the previous steps)

summary: - [2.6] [UI] Malformed input in the IP addr field in "power parameters"
- causes part of SQL error to be shown
+ [2.6] Malformed input in the IP addr field in "power parameters" causes
+ part of SQL error to be shown
Changed in maas:
status: New → Triaged
importance: Undecided → High
Revision history for this message
Adam Collard (adam-collard) wrote :

We should check for SQL injection vulnerabilities here, and also not expose error messages that come directly from the db

summary: - [2.6] Malformed input in the IP addr field in "power parameters" causes
- part of SQL error to be shown
+ Malformed input in the IP addr field in "power parameters" causes part
+ of SQL error to be shown
Changed in maas:
milestone: none → 3.5.0
Changed in maas:
milestone: 3.5.0 → 3.5.x
To post a comment you must log in.