[2.3, HWTv2] Runtime resets back to 0 after 24 hours

Bug #1733015 reported by Andres Rodriguez
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
MAAS
Fix Released
High
Unassigned

Bug Description

I left testing scripts running for over 24 hours, and I noticed that the machine started counting from 0 after 24 hours.

The test has been running for 24hrs+, but it shows: 04:21:24

Related branches

Changed in maas:
importance: Undecided → High
status: New → Triaged
milestone: none → 2.3.0
Revision history for this message
Andres Rodriguez (andreserl) wrote :

maybe it didn't reset after 24hrs, but actually, it reset when changing dates ?

Revision history for this message
Mike Pontillo (mpontillo) wrote :

If you change your system clock you can expect bad things to happen.

I strongly suspect this is a display issue that can be fixed in the Javascript code; we store absolute timestamps in the database.

Changed in maas:
status: Triaged → Fix Committed
Changed in maas:
status: Fix Committed → Fix Released
To post a comment you must log in.