EESchema - Power symbols don't come up when running find
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
KiCad |
Fix Committed
|
High
|
Jeff Young |
Bug Description
Somehow I ended up with two power symbols with two identical reference number. Well, it happened when I copied and pasted a piece of schematic from a different project and they didn't get reset. Regardless, every time I attempted to annotate schematic I was getting an error message about identical #PWR190 symbols. However when I tried to find them, the search apparently ignores power symbols and reference numbers for power symbols are not showing. So I actually had to play a game of delete half of schematic - run annotate, see if the error was solved and then repeat on the offending half until I could reduce the scope of the search.
Application: KiCad
Version: (5.99.0-
Libraries:
wxWidgets 3.0.4
libcurl/7.61.1 OpenSSL/1.1.1 (WinSSL) zlib/1.2.11 brotli/1.0.6 libidn2/2.0.5 libpsl/0.21.0 (+libidn2/2.1.1) nghttp2/1.34.0
Platform: Windows 8 (build 9200), 64-bit edition, 64 bit, Little endian, wxMSW
Build Info:
Build date: Oct 16 2019 21:05:43
wxWidgets: 3.0.4 (wchar_t,wx containers,
Boost: 1.68.0
OpenCASCADE Community Edition: 6.9.1
Curl: 7.61.1
Compiler: GCC 8.2.0 with C++ ABI 1013
Build settings:
KICAD_
KICAD_
KICAD_
KICAD_
KICAD_
KICAD_
BUILD_
KICAD_
KICAD_
KICAD_SPICE=ON
tags: | added: eeschema |
@Art, are you sure it wasn't just because power symbol references aren't usually shown? Or maybe there was something else that I haven't managed to duplicate. See the attached graphic which shows my simple test-case.