Zone stitching vias don't have nets updated in v6
Bug #1830102 reported by
Seth Hillbrand
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
KiCad |
Fix Committed
|
Medium
|
Seth Hillbrand |
Bug Description
Importing an Eagle project from [1], version 5.1.x does well. There are no unconnected nets and the netnames are properly assigned to all items on import.
In version 6, there are 4 vias that stitch together two zones (no tracks connected). These keep an original net name from Eagle instead of being updated. The vias are then unconnected as are the two zones.
Additionally (not sure if it is related), performing an "Update PCB from Schematic" changes more items on the board.
I am attaching the KiCad projects that resulted from importing v5 as well as v6
tags: | added: eagle eeschema import pcbnew |
Changed in kicad: | |
milestone: | none → 6.0.0-rc1 |
To post a comment you must log in.
Looks like this issue is in the PcbNew netlist importer; the two netlists generated by Eeschema in V5 and V6 are functionally identical. If I Use PcbNew V6 (master) and import the netlist generated by V5 I also get the disconnected vias.