eeschema incorrectly merges nets

Bug #1826588 reported by mark van doesburg
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
KiCad
Fix Committed
High
Jon Evans

Bug Description

When creating two instances of the same sheet, eeschema merges the nets of all ports.

Application: kicad
Version: (5.1.0-368-g69cdb4a76), release build
Libraries:
    wxWidgets 3.0.4
    libcurl/7.64.1 OpenSSL/1.1.1b zlib/1.2.11 libidn2/2.1.1 libpsl/0.20.2 (+libidn2/2.1.1) libssh2/1.8.2 nghttp2/1.37.0
Platform: Linux 4.19.25 x86_64, 64 bit, Little endian, wxGTK
Build Info:
    wxWidgets: 3.0.4 (wchar_t,wx containers,compatible with 2.8) GTK+ 2.24
    Boost: 1.69.0
    OpenCASCADE Technology: 7.3.0
    Curl: 7.64.1
    Compiler: GCC 8.3.0 with C++ ABI 1013
Build settings:
    USE_WX_GRAPHICS_CONTEXT=OFF
    USE_WX_OVERLAY=OFF
    KICAD_SCRIPTING=ON
    KICAD_SCRIPTING_MODULES=ON
    KICAD_SCRIPTING_PYTHON3=OFF
    KICAD_SCRIPTING_WXPYTHON=ON
    KICAD_SCRIPTING_WXPYTHON_PHOENIX=OFF
    KICAD_SCRIPTING_ACTION_MENU=ON
    BUILD_GITHUB_PLUGIN=ON
    KICAD_USE_OCE=OFF
    KICAD_USE_OCC=ON
    KICAD_SPICE=ON

Tags: eeschema
Revision history for this message
mark van doesburg (mvdoesbur) wrote :

This project demonstrates the issue. If one of the nets on the LIVE port is highlighted, the other one is also highlighted. The same merging happens on the PCB..

Jon Evans (craftyjon)
Changed in kicad:
milestone: none → 6.0.0-rc1
assignee: nobody → Jon Evans (craftyjon)
Jon Evans (craftyjon)
Changed in kicad:
importance: Undecided → High
status: New → Triaged
tags: added: eeschema
Revision history for this message
Jon Evans (craftyjon) wrote :

This should have been fixed by recent commits, please re-open if you can reproduce after commit 6d918ea

Changed in kicad:
status: Triaged → Fix Committed
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Bug attachments

Remote bug watches

Bug watches keep track of this bug in other bug trackers.