Pcbnew: Solder mask min with not save if 0

Bug #1817599 reported by Matteo Costa on 2019-02-25
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
KiCad
Undecided
Seth Hillbrand

Bug Description

Application: kicad
Version: (5.0.2)-1, release build
Libraries:
    wxWidgets 3.0.4
    libcurl/7.61.1 OpenSSL/1.1.1 (WinSSL) zlib/1.2.11 brotli/1.0.6 libidn2/2.0.5 libpsl/0.20.2 (+libidn2/2.0.5) nghttp2/1.34.0
Platform: Windows 8 (build 9200), 64-bit edition, 64 bit, Little endian, wxMSW
Build Info:
    wxWidgets: 3.0.4 (wchar_t,wx containers,compatible with 2.8)
    Boost: 1.68.0
    OpenCASCADE Community Edition: 6.9.1
    Curl: 7.61.1
    Compiler: GCC 8.2.0 with C++ ABI 1013

Build settings:
    USE_WX_GRAPHICS_CONTEXT=OFF
    USE_WX_OVERLAY=OFF
    KICAD_SCRIPTING=ON
    KICAD_SCRIPTING_MODULES=ON
    KICAD_SCRIPTING_WXPYTHON=ON
    KICAD_SCRIPTING_ACTION_MENU=ON
    BUILD_GITHUB_PLUGIN=ON
    KICAD_USE_OCE=ON
    KICAD_USE_OCC=OFF
    KICAD_SPICE=ON

In Setup -> Pads to Mask Clearance set the value for 'Solder mas min width' is to 0, when the project is saved the value is not saved at all. The line '(solder_mask_min_width x.xxxx)' is removed from the kicad_pcb file.
At the next load of the project the default value is restore without any warning leading to possible problem if the gerber are rebuilt.

Seth Hillbrand (sethh) wrote :

Fixed in 0c723778f0

Changed in kicad:
assignee: nobody → Seth Hillbrand (sethh)
milestone: none → 5.1.0
status: New → Fix Committed
Changed in kicad:
status: Fix Committed → Fix Released
To post a comment you must log in.