pcbnew: vias not selectable unless top layer is turned on
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
KiCad |
Fix Released
|
High
|
Jon Evans |
Bug Description
cant select TH-vias unless i turn on F.cu and/or B.Cu (visibility check box)
Application: kicad
Version: (5.0.0-
Libraries:
wxWidgets 3.0.3
libcurl/7.54.1 OpenSSL/1.0.2l zlib/1.2.11 libssh2/1.8.0 nghttp2/1.23.1 librtmp/2.3
Platform: Windows 7 (build 7601, Service Pack 1), 64-bit edition, 64 bit, Little endian, wxMSW
Build Info:
wxWidgets: 3.0.3 (wchar_t,wx containers,
Boost: 1.60.0
Curl: 7.54.1
Compiler: GCC 7.1.0 with C++ ABI 1011
Build settings:
USE_
USE_
KICAD_
KICAD_
KICAD_
KICAD_
BUILD_
KICAD_
KICAD_SPICE=ON
Changed in kicad: | |
assignee: | nobody → Jon Evans (craftyjon) |
Changed in kicad: | |
status: | New → Confirmed |
importance: | Undecided → High |
milestone: | none → 5.0.0-rc2 |
Changed in kicad: | |
status: | Fix Committed → Fix Released |
@Jon, I think Andrzej posted a patch to fix this on the dev mailing list. You might want to take a look at that before you fix this.