ERC does not find unconnected Power Ports

Bug #1639400 reported by David Pearce
30
This bug affects 6 people
Affects Status Importance Assigned to Milestone
KiCad
Expired
Wishlist

Bug Description

Eeschema bug
Power Ports have a "Pin" like a component symbol, but ERC does not flag if the Power Port is not attached to a wire segment. The consequence is that a Power Port can be placed on a wire and fail to name the net correctly, resulting islands of isolated tracks.
The attached screenshot shows an "orphan" Power Port and an unconnected resistor. The resistor IS detected by ERC

Application: kicad
Version: 4.0.4-stable release build
wxWidgets: Version 3.0.2 (debug,wchar_t,compiler with C++ ABI 1009,GCC 5.2.0,wx containers,compatible with 2.8)
Platform: Windows 7 (build 7601, Service Pack 1), 64-bit edition, 64 bit, Little endian, wxMSW
Boost version: 1.57.0
         USE_WX_GRAPHICS_CONTEXT=OFF
         USE_WX_OVERLAY=OFF
         KICAD_SCRIPTING=ON
         KICAD_SCRIPTING_MODULES=ON
         KICAD_SCRIPTING_WXPYTHON=ON
         USE_FP_LIB_TABLE=HARD_CODED_ON
         BUILD_GITHUB_PLUGIN=ON

Tags: eeschema erc
Revision history for this message
David Pearce (halzia) wrote :
Revision history for this message
Gaz (questuk) wrote :

Hi,

I have discussed this on the following forum and its agreed its a fault.

https://forum.kicad.info/t/erc-check-misses-unconnected-5v-and-0v/4385/31

Thanks

Gaz

Revision history for this message
Gaz (questuk) wrote :

PS

It also has an example in zip format called TEST on the above website on that page.

Regards

Gaz

Jon Evans (craftyjon)
tags: added: erc
Changed in kicad:
importance: Undecided → Wishlist
Revision history for this message
Rene Poeschl (poeschlr) wrote :

There is an inconsistency in deceding what is a wishlist item and what is a bug. The similar bug for hirarchical labels is marked as importance "medium" https://bugs.launchpad.net/kicad/+bug/1781725

---

It seems global labels have the same problem. So i think we can make one large bug report that just says: "ERC does not detect any type of unconnected labels"

Revision history for this message
Seth Hillbrand (sethh) wrote :

This is wishlist because the discussed failure mode is not applicable anymore. Junctions are added automatically, connecting power pins to wires. The extra check of isolated power pins is nice to have but now the pin will need to be physically separated from the wire for it to occur.

I marked the referenced report higher because it is harder to see when hierarchical labels don't connect to anything at the parent sheet.

Revision history for this message
Rene Poeschl (poeschlr) wrote :

Another Related report this time about labels: https://bugs.launchpad.net/kicad/+bug/1802008

Jon Evans (craftyjon)
Changed in kicad:
assignee: nobody → Jon Evans (craftyjon)
milestone: none → 6.0.0-rc1
tags: added: eeschema
Jon Evans (craftyjon)
Changed in kicad:
status: New → Triaged
Revision history for this message
KiCad Janitor (kicad-janitor) wrote :

KiCad bug tracker has moved to Gitlab. This report is now available here: https://gitlab.com/kicad/code/kicad/-/issues/2038

Changed in kicad:
status: Triaged → Expired
To post a comment you must log in.