PNS router generates multiple via (duplicates of the same via)

Bug #1473247 reported by Pierre Parent
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
KiCad
Fix Released
Medium
Unassigned

Bug Description

This bug concerns Version 4.0.0-rc1 compiled form revno 5886.

Using the PNS router for a while generates a lot of multiple via at the exact same location. I cannot say exaclty what triggers it but the problem seems to appear in many different circonstances.

(I had to write a program to remove those duplicates from my kicad_pcb file.)

Tags: cern pcbnew pns
description: updated
Revision history for this message
Chris Pavlina (pavlina-chris) wrote :

I can confirm this - have been seeing it quite a bit in my projects too.

Edit -> Cleanup Tracks and Vias should take care of it, so I'm not going to consider this a very high priority bug, but it would definitely be nice if PNS didn't do this.

Changed in kicad:
status: New → Confirmed
importance: Undecided → Medium
tags: added: cern pcbnew pns
Revision history for this message
Pierre Parent (pierre-parent-k) wrote :

In my case Edit -> Cleanup Tracks and Vias does not solve the problem.

Revision history for this message
Maciej Suminski (orsonmmz) wrote :

Hi Pierre,

It is fixed in 5897, please verify.

Regards,
Orson

Changed in kicad:
status: Confirmed → Fix Committed
Jon Neal (reportingsjr)
Changed in kicad:
status: Fix Committed → Fix Released