hp-firmware crashes when run without an x server and without '-i'

Bug #1605822 reported by Alastair Hughes
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
HPLIP
In Progress
Medium
Unassigned

Bug Description

hp-firmware crashes when run without an x server and without '-i' due to line 102 (in hplip 3.16.7) being INTERACTIVE_MODE4 instead of INTERACTIVE_MODE.

Revision history for this message
Alastair Hughes (hobbitalastair-deactivatedaccount) wrote :
Revision history for this message
Ajay Kedar (ajay-kedar) wrote :

Hi,

In order to change from INTERACTIVE_MODE4 to INTERACTIVE_MODE apply the attached patch.
Steps to apply patch.
1. Go to HPLIP source code directory.
2. Apply patch using command "patch firmware.py < patch1.diff".
3. Install code using command "sudo make install"

And the fix will be included in the next release of HPLIP.
Thanks.

Ajay Kedar (ajay-kedar)
Changed in hplip:
status: New → In Progress
Changed in hplip:
importance: Undecided → Medium
To post a comment you must log in.