If a worker starts while the gearman server is down, it does not establish a connection when the server comes up

Bug #693480 reported by Omry Yadan on 2010-12-22
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Gearman Java
Medium
Eric Lambert

Bug Description

Reproduce:
1. shut down gearman job server
2. start worker
3. start up gearman job server
4. check that the worker is not registered (telnet server 4730)

Omry Yadan (omry) wrote :

expected behavior:
worker should register functions internally, and register with the job server when it becomes available.

Eric Lambert (elambert) on 2011-01-12
Changed in gearman-java:
assignee: nobody → Eric Lambert (elambert)
importance: Undecided → Medium
Eric Lambert (elambert) on 2012-05-05
Changed in gearman-java:
milestone: none → 0.05
Eric Lambert (elambert) on 2012-09-25
Changed in gearman-java:
milestone: 0.05 → none