carousel required fields
Bug #1851515 reported by
Jason Etheridge
This bug affects 5 people
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Evergreen |
Confirmed
|
Medium
|
Unassigned |
Bug Description
If Owner is not supplied when creating/editing carousels, we get an uncaught DB INSERT error. A similar thing happens with Sequence when linking carousels to libraries.
tags: | added: carousel |
Changed in evergreen: | |
status: | New → Confirmed |
Changed in evergreen: | |
importance: | Undecided → Medium |
tags: |
added: admin-pages opac-carousel removed: carousel |
To post a comment you must log in.
Confirmed on EG 3.11
Would the correct way to fix this be to mark the
"Sequence Number" field with oils_obj: required= "true" of the ccou class in the Fieldmapper?
The Owner field of cc (container. carousel) is already marked as required in the FM though. So maybe the problem is that the eg-org-select doesn't detect setting the required setting?