Add alarm filtering to analog output records

Bug #1573462 reported by Ralph Lange
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
EPICS Base
Confirmed
Wishlist
Ralph Lange

Bug Description

The alarm hysteresis filtering (AFTC and AFVL fields) was added to Base 3.14.11 in 2009.

The calc and ai records received this filter (fields and algorithm patches), the calcout and ao records did not.

As the analog output records implement the same alarm functionality as the input records, especially as calcout is basically defined as "calc plus output" and sometimes marketed as a replacement for calc, they should get the mechanism.

Revision history for this message
Ralph Lange (ralph-lange) wrote :

dfanout, too.

Changed in epics-base:
status: New → Confirmed
importance: Undecided → Wishlist
assignee: nobody → Ralph Lange (ralph-lange)
To post a comment you must log in.