test_volume_migrate_attached failed on Dell SC driver

Bug #1826840 reported by Sam Wan
12
This bug affects 2 people
Affects Status Importance Assigned to Milestone
Cinder
Invalid
Undecided
Unassigned

Bug Description

tempest test case 'tempest.scenario.test_volume_migrate_attached.TestVolumeMigrateRetypeAttached.test_volume_migrate_attached' failed on Dell SC driver for both SC and iSCSI.

FC error log: http://publiclogs.emc.com/97/655597/1/check/DellEMC_SC_FC/531f32c/DellEMC_SC_FC/8/logs/screen-c-vol.txt.gz
======
Apr 25 02:56:59.673119 dellscfc cinder-volume[17715]: DEBUG cinder.volume.drivers.dell_emc.sc.storagecenter_api [req-b5af6fbe-6099-4af7-a1c0-9aad40dc0703 req-00f7af15-6233-4329-b1da-0efd50488139 tempest-TestVolumeMigrateRetypeAttached-1555718387 None] post: ApiConnection/Logout data: {} {{(pid=17902) post /opt/stack/new/cinder/cinder/volume/drivers/dell_emc/sc/storagecenter_api.py:250}}
Apr 25 02:56:59.680336 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager [req-b5af6fbe-6099-4af7-a1c0-9aad40dc0703 req-00f7af15-6233-4329-b1da-0efd50488139 tempest-TestVolumeMigrateRetypeAttached-1555718387 None] Terminate volume connection failed: Bad or unexpected response from the storage volume backend API: Terminate connection unable to connect to backend.: cinder.exception.VolumeBackendAPIException: Bad or unexpected response from the storage volume backend API: Terminate connection unable to connect to backend.
Apr 25 02:56:59.680812 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager Traceback (most recent call last):
Apr 25 02:56:59.680948 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4579, in _connection_terminate
Apr 25 02:56:59.681094 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager force=force)
Apr 25 02:56:59.681247 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager File "/opt/stack/new/cinder/cinder/volume/drivers/dell_emc/sc/storagecenter_fc.py", line 311, in terminate_connection
Apr 25 02:56:59.681388 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager data=_('Terminate connection unable to connect to backend.'))
Apr 25 02:56:59.681524 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager cinder.exception.VolumeBackendAPIException: Bad or unexpected response from the storage volume backend API: Terminate connection unable to connect to backend.
Apr 25 02:56:59.681655 dellscfc cinder-volume[17715]: ERROR cinder.volume.manager
Apr 25 02:56:59.681802 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server [req-b5af6fbe-6099-4af7-a1c0-9aad40dc0703 req-00f7af15-6233-4329-b1da-0efd50488139 tempest-TestVolumeMigrateRetypeAttached-1555718387 None] Exception during message handling: cinder.exception.VolumeBackendAPIException: Bad or unexpected response from the storage volume backend API: Terminate volume connection failed: Bad or unexpected response from the storage volume backend API: Terminate connection unable to connect to backend.
Apr 25 02:56:59.682142 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server Traceback (most recent call last):
Apr 25 02:56:59.682273 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4579, in _connection_terminate
Apr 25 02:56:59.682407 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server force=force)
Apr 25 02:56:59.682537 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/drivers/dell_emc/sc/storagecenter_fc.py", line 311, in terminate_connection
Apr 25 02:56:59.682670 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server data=_('Terminate connection unable to connect to backend.'))
Apr 25 02:56:59.682809 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server cinder.exception.VolumeBackendAPIException: Bad or unexpected response from the storage volume backend API: Terminate connection unable to connect to backend.
Apr 25 02:56:59.682945 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server
Apr 25 02:56:59.683079 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server During handling of the above exception, another exception occurred:
Apr 25 02:56:59.683211 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server
Apr 25 02:56:59.683341 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server Traceback (most recent call last):
Apr 25 02:56:59.683470 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/usr/local/lib/python3.5/dist-packages/oslo_messaging/rpc/server.py", line 166, in _process_incoming
Apr 25 02:56:59.683599 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server res = self.dispatcher.dispatch(message)
Apr 25 02:56:59.683732 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/usr/local/lib/python3.5/dist-packages/oslo_messaging/rpc/dispatcher.py", line 265, in dispatch
Apr 25 02:56:59.683873 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server return self._do_dispatch(endpoint, method, ctxt, args)
Apr 25 02:56:59.684011 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/usr/local/lib/python3.5/dist-packages/oslo_messaging/rpc/dispatcher.py", line 194, in _do_dispatch
Apr 25 02:56:59.684144 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server result = func(ctxt, **new_args)
Apr 25 02:56:59.684283 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4615, in attachment_delete
Apr 25 02:56:59.684417 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server self._do_attachment_delete(context, vref, attachment_ref)
Apr 25 02:56:59.684547 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4622, in _do_attachment_delete
Apr 25 02:56:59.684682 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server attachment)
Apr 25 02:56:59.684815 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4587, in _connection_terminate
Apr 25 02:56:59.684952 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server raise exception.VolumeBackendAPIException(data=err_msg)
Apr 25 02:56:59.685088 dellscfc cinder-volume[17715]: ERROR oslo_messaging.rpc.server cinder.exception.VolumeBackendAPIException: Bad or unexpected response from the storage volume backend API: Terminate volume connection failed: Bad or unexpected response from the storage volume backend API: Terminate connection unable to connect to backend.
======

iSCSI error log: http://publiclogs.emc.com/97/655597/1/check/DellEMC_SC_iSCSI/d333490/DellEMC_SC_iSCSI/8/logs/screen-c-vol.txt.gz
======
Apr 25 04:07:33.857119 dellscslave cinder-volume[6422]: DEBUG cinder.volume.drivers.dell_emc.sc.storagecenter_api [req-7a2fc635-a0d9-41d8-a725-09676011a1c7 req-7be344f1-cc79-4df7-a114-682a2801fa1f tempest-TestVolumeMigrateRetypeAttached-64622798 None] post: ApiConnection/Logout data: {} {{(pid=6577) post /opt/stack/new/cinder/cinder/volume/drivers/dell_emc/sc/storagecenter_api.py:250}}
Apr 25 04:07:33.882531 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager [req-7a2fc635-a0d9-41d8-a725-09676011a1c7 req-7be344f1-cc79-4df7-a114-682a2801fa1f tempest-TestVolumeMigrateRetypeAttached-64622798 None] Terminate volume connection failed: Terminate connection failed: cinder.exception.VolumeBackendAPIException: Terminate connection failed
Apr 25 04:07:33.882703 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager Traceback (most recent call last):
Apr 25 04:07:33.882822 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4579, in _connection_terminate
Apr 25 04:07:33.882922 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager force=force)
Apr 25 04:07:33.883024 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager File "/opt/stack/new/cinder/cinder/volume/drivers/dell_emc/sc/storagecenter_iscsi.py", line 305, in terminate_connection
Apr 25 04:07:33.883119 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager _('Terminate connection failed'))
Apr 25 04:07:33.883215 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager cinder.exception.VolumeBackendAPIException: Terminate connection failed
Apr 25 04:07:33.883311 dellscslave cinder-volume[6422]: ERROR cinder.volume.manager
Apr 25 04:07:33.885106 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server [req-7a2fc635-a0d9-41d8-a725-09676011a1c7 req-7be344f1-cc79-4df7-a114-682a2801fa1f tempest-TestVolumeMigrateRetypeAttached-64622798 None] Exception during message handling: cinder.exception.VolumeBackendAPIException: Bad or unexpected response from the storage volume backend API: Terminate volume connection failed: Terminate connection failed
Apr 25 04:07:33.885265 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server Traceback (most recent call last):
Apr 25 04:07:33.885480 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4579, in _connection_terminate
Apr 25 04:07:33.885671 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server force=force)
Apr 25 04:07:33.885984 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/drivers/dell_emc/sc/storagecenter_iscsi.py", line 305, in terminate_connection
Apr 25 04:07:33.886231 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server _('Terminate connection failed'))
Apr 25 04:07:33.886382 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server cinder.exception.VolumeBackendAPIException: Terminate connection failed
Apr 25 04:07:33.886483 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server
Apr 25 04:07:33.886581 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server During handling of the above exception, another exception occurred:
Apr 25 04:07:33.886682 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server
Apr 25 04:07:33.886776 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server Traceback (most recent call last):
Apr 25 04:07:33.887365 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/usr/local/lib/python3.5/dist-packages/oslo_messaging/rpc/server.py", line 166, in _process_incoming
Apr 25 04:07:33.887469 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server res = self.dispatcher.dispatch(message)
Apr 25 04:07:33.887581 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/usr/local/lib/python3.5/dist-packages/oslo_messaging/rpc/dispatcher.py", line 265, in dispatch
Apr 25 04:07:33.887683 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server return self._do_dispatch(endpoint, method, ctxt, args)
Apr 25 04:07:33.887799 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/usr/local/lib/python3.5/dist-packages/oslo_messaging/rpc/dispatcher.py", line 194, in _do_dispatch
Apr 25 04:07:33.887908 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server result = func(ctxt, **new_args)
Apr 25 04:07:33.888163 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4615, in attachment_delete
Apr 25 04:07:33.888293 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server self._do_attachment_delete(context, vref, attachment_ref)
Apr 25 04:07:33.888400 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4622, in _do_attachment_delete
Apr 25 04:07:33.888577 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server attachment)
Apr 25 04:07:33.888678 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server File "/opt/stack/new/cinder/cinder/volume/manager.py", line 4587, in _connection_terminate
Apr 25 04:07:33.888777 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server raise exception.VolumeBackendAPIException(data=err_msg)
Apr 25 04:07:33.888874 dellscslave cinder-volume[6422]: ERROR oslo_messaging.rpc.server cinder.exception.VolumeBackendAPIException: Bad or unexpected response from the storage volume backend API: Terminate volume connection failed: Terminate connection failed
======

Tags: dell drivers sc
Sam Wan (sam-wan)
tags: added: dell drivers sc
Revision history for this message
Jean Pierre Roquesalane (jproque15130) wrote :

Dell SC are EOL, marking this as invalid.

Changed in cinder:
status: New → Invalid
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.