3PAR iSCSI creates new LUN ids for each multipath attachment

Bug #1551994 reported by Walt Boring
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Cinder
Fix Released
Medium
Walt Boring

Bug Description

When multipath is enabled on the n-cpu host, the 3PAR iSCSI driver will create a new VLUN with a new LUN ID for each path for the same volume. The 3PAR should use the same LUN id for each path.

Changed in cinder:
importance: Undecided → Medium
milestone: none → mitaka-3
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to cinder (master)

Fix proposed to branch: master
Review: https://review.openstack.org/286889

Changed in cinder:
status: New → In Progress
Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix proposed to cinder (stable/liberty)

Fix proposed to branch: stable/liberty
Review: https://review.openstack.org/287386

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to cinder (master)

Reviewed: https://review.openstack.org/286889
Committed: https://git.openstack.org/cgit/openstack/cinder/commit/?id=f813bde3c5b2ec357a51b8172db64e31a967cc35
Submitter: Jenkins
Branch: master

commit f813bde3c5b2ec357a51b8172db64e31a967cc35
Author: Walter A. Boring IV <email address hidden>
Date: Tue Mar 1 07:22:21 2016 -0800

    3PAR use same LUN id for each export path

    When multipath is enabled, and the 3PAR driver is configured
    to export a VLUN over N iSCSI IP(ports), we now use the same
    LUN ID for each iSCSI IP export. Previously, when we would
    export a volume over N iSCSI ports, we would get a new LUN ID
    for each iSCSI port.

    Change-Id: Ide0ce373a14f348a554688dee9b699feed3c5f26
    Closes-Bug: #1551994

Changed in cinder:
status: In Progress → Fix Released
Revision history for this message
Thierry Carrez (ttx) wrote : Fix included in openstack/cinder 8.0.0.0rc1

This issue was fixed in the openstack/cinder 8.0.0.0rc1 release candidate.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote : Fix merged to cinder (stable/liberty)

Reviewed: https://review.openstack.org/287386
Committed: https://git.openstack.org/cgit/openstack/cinder/commit/?id=feac52b6efecd17dbcc161f6da749b4819a8f477
Submitter: Jenkins
Branch: stable/liberty

commit feac52b6efecd17dbcc161f6da749b4819a8f477
Author: Walter A. Boring IV <email address hidden>
Date: Wed Mar 2 03:05:29 2016 -0800

    3PAR use same LUN id for each export path

    When multipath is enabled, and the 3PAR driver is configured
    to export a VLUN over N iSCSI IP(ports), we now use the same
    LUN ID for each iSCSI IP export. Previously, when we would
    export a volume over N iSCSI ports, we would get a new LUN ID
    for each iSCSI port.

    Master Change id: Ide0ce373a14f348a554688dee9b699feed3c5f26

    Change-Id: If40b842e59e384db6eee11e9fa843e4ead6411d4
    Closes-Bug: #1551994

tags: added: in-stable-liberty
Revision history for this message
Doug Hellmann (doug-hellmann) wrote : Fix included in openstack/cinder 7.0.2

This issue was fixed in the openstack/cinder 7.0.2 release.

Revision history for this message
OpenStack Infra (hudson-openstack) wrote :

This issue was fixed in the openstack/cinder 7.0.2 release.

To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.