Inconsistent behavior with FOS version check for BCZM

Bug #1338536 reported by deepali verneya
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Cinder
Invalid
Undecided
Unassigned

Bug Description

When I try attaching 3PAR FC volume to an instance with multiple switch and pre-zoning ,attach volume fails with error “Make sure switch is running firmware v6.4 or higher to caller” occasionally

Step to reproduce:

1. Clear all configurations from switch .(use cfgclear and thn cfgsave)
2. Create zone with one initiator and one target and save the configuration.
3. Configure Brocade zone manager.
4. Create 3PAR FC volume
5. Attach volume to instance

Observation:
Attachment fails with error “Failed adding connection for fabric=None: Error:Failed to get SAN context Unsupported firmware on switch xx.xx.xx.xx . Make sure switch is running firmware v6.4 or higher” .Even though switch FOS version was v7.0.0

Switch Firmware Versions-
Switch 1 : :
SVSCDLSAN07:FID128:admin> version
Kernel: 2.6.14.2
Fabric OS: v7.0.0c
Made on: Thu Oct 27 00:27:49 2011
Flash: Mon Mar 25 16:27:53 2013
BootProm: 1.0.9
SVSCDLSAN07:FID128:admin>

Switch 2 : :
SVSCDLSAN08:FID128:admin> version
Kernel: 2.6.14.2
Fabric OS: v7.0.0c
Made on: Thu Oct 27 00:27:49 2011
Flash: Thu Jan 10 18:52:24 2013
BootProm: 1.0.9
SVSCDLSAN08:FID128:admin>

Tags: zonemanager
Revision history for this message
deepali verneya (deepali-verneya) wrote :
Revision history for this message
Michael Denny (michael-denny) wrote :

Attach your cinder.conf

Changed in cinder:
status: New → Incomplete
Revision history for this message
Angela Smith (aallen-m) wrote :

This is not an issue with invalid firmware, but an issue with MAX logins for user 'admin' has been reached. See log output for CLI request to retrieve version info: Sorry! Max remote sessions for login:admin is 2.

To prevent this, do not open a SSH session outside of OpenStack to the switch. Also, as is recommended, use 'zoneadmin' login, which allows 4 concurrent SSH sessions.

Revision history for this message
deepali verneya (deepali-verneya) wrote :

cinder.conf attached

Revision history for this message
Michael Denny (michael-denny) wrote :

zoning_mode=fabric needs to be in [DEFAULT] section

Changed in cinder:
status: Incomplete → Invalid
To post a comment you must log in.