combination alarm state retrieval always fails
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
Ceilometer |
Fix Released
|
High
|
Eoghan Glynn |
Bug Description
The retrieval of state for the constituent alarms always fails for combination alarms, due to an incorrect attribute of ceilometerclient being used:
2013-10-09 19:46:26.731 24995 ERROR ceilometer.
2013-10-09 19:46:26.731 24995 TRACE ceilometer.
2013-10-09 19:46:26.731 24995 TRACE ceilometer.
2013-10-09 19:46:26.731 24995 TRACE ceilometer.
2013-10-09 19:46:26.731 24995 TRACE ceilometer.
The correct attribute is pluralized, i.e. _client.alarms as opposed to _client.alarm.
As a result combination alarms can never be successfully evaluated.
Changed in ceilometer: | |
status: | New → In Progress |
importance: | Undecided → High |
assignee: | nobody → Eoghan Glynn (eglynn) |
tags: | added: havana-rc-potential |
Changed in ceilometer: | |
milestone: | none → havana-rc2 |
tags: | removed: havana-rc-potential |
Changed in ceilometer: | |
milestone: | havana-rc2 → 2013.2 |
Fix proposed to branch: master /review. openstack. org/50714
Review: https:/